Lapp H05V2-K Installation Wire - Black - 4515013-100 [100 Meters]
![Lapp H05V2-K Installation Wire - Black - 4515013-100 [100 Meters]](https://shopping-cdn.redbrainapis.com/v/1a6c296fae587c47c76163c5b8f5f8fc76237473799c8468f198f8332ff7bfb4_500x500.jpeg)
Best current price£29.82from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Lapp Black H05v2-K Installation Wire - 4515011-100 [100 Meters]
Visit shop![Lapp H05V2-K Installation Wire - Black - 4515013-100 [100 Meters]](https://shopping-cdn.redbrainapis.com/v/1a6c296fae587c47c76163c5b8f5f8fc76237473799c8468f198f8332ff7bfb4_500x500.jpeg)
Best current price£29.82from Tameson UK
Shopping.co.uk recommended and popular offers
Lapp Black H05v2-K Installation Wire - 4515011-100 [100 Meters]
Visit shop6 offers from £29.82 - £111.13
View price history by clicking the chart icon.
This guide is for electricians and DIY enthusiasts working on electrical installations. The Lapp H05V2-K 90° installation wire offers flexibility and durability for various applications, though its specific voltage rating requires careful consideration. It features a class 5 flexible conductor, PVC insulation, and a black outer sheath, meeting CPR Euro fire class eca standards with a nominal voltage of 500V.
| Colour | Black |
|---|---|
| Model Part Number | 4515013 |
| Brand | LAPP |
'H05' indicates a harmonized cable for 500V applications. 'V2' refers to the type of PVC insulation. 'K' signifies a flexible conductor (Class 5).
The nominal voltage rating is 500V. It is important not to exceed this voltage for safe operation.
The PVC insulation is suitable for general indoor use. For outdoor applications, consult the product specifications for UV and weather resistance, or consider cables specifically designed for such environments.
The nominal conductor cross-section is 1mm².
This designation means the wire meets specific European standards for reaction to fire in building applications, indicating a certain level of fire performance.
While it has a flexible conductor (Class 5), it is designed for fixed installations. It is not intended for applications that require frequent or continuous movement, such as typical extension cords.
The outer diameter of this wire is approximately 2.8mm.
While designed for flexibility, ensure the wire has reached ambient temperature. Extreme cold can temporarily reduce flexibility. Check that you are not attempting to bend it tighter than its recommended minimum bend radius.
Use a suitable wire stripping tool that is designed for fine-stranded conductors. Ensure the stripping tool does not damage the conductor strands. Avoid excessive force when stripping or terminating.
Verify that the wire's cross-sectional area (1mm²) and voltage rating (500V) are appropriate for the current load. Consult an electrician to ensure the circuit is correctly sized and that there are no short circuits or excessive resistance in the connections.