Lapp H05V2-K Installation Wire - 4515001-100 [100 Meters] - Green

Lapp H05V2-K 90° xx installation wire, composition conductor class 5 = flexible, nominal conductor...

Best current price£27.76from Tameson UK

Colour

All Offers

7 offers from £27.76 - £90.45

View price history by clicking the chart icon.

Tameson UKLapp Green H05v2-K Installation Wire - 4515121-100 [100 Meters]
Free delivery in 1–3 days
£27.76
Visit shop

Product Information

Full details

This guide is for electricians and DIYers working on low-voltage electrical installations. The Lapp H05V2-K 90° installation wire offers flexibility and a high-quality PVC insulation for reliable connections in demanding environments. A key consideration is its specific voltage rating, ensuring it's used within its designed operational limits.

All features

ColourGreen
Model Part Number4515001
BrandLAPP

Extended Product Information

FAQs

What is the primary use of the H05V2-K 90° wire?

This wire is designed for fixed, low-voltage electrical installations within buildings, such as for internal wiring, control systems, and lighting circuits.

Can this wire be used outdoors?

The H05V2-K designation with PVC insulation is generally intended for indoor applications. For outdoor use, consult manufacturer specifications for suitability or consider cables with enhanced weather-resistant sheathing.

What does 'H05V2-K' mean?

'H05' indicates a harmonized cable for low voltage up to 500V to earth. 'V2' refers to a PVC insulation rated for 90°C. 'K' signifies a flexible conductor.

Is the green/yellow wire a ground wire?

Yes, the green/yellow conductor is universally recognized as the protective earth (ground) conductor in electrical installations.

What is the maximum voltage this wire can handle?

The nominal voltage for this wire is 500V. It should be used in circuits operating at or below this voltage.

Can I use this wire for mains power in a house?

The 0.5mm² cross-section and 500V rating are suitable for specific low-voltage circuits within a building, but not typically for general mains power distribution which requires larger cross-sections and higher voltage ratings.

Troubleshooting

Wire is stiff and difficult to bend.

Ensure the wire is at room temperature. Extreme cold can temporarily reduce flexibility. Avoid forcing bends that could damage the conductor or insulation.

Intermittent connection.

Check termination points for loose connections, corrosion, or debris. Re-strip the wire if necessary and ensure a secure connection with appropriate connectors or terminals.

Insulation appears damaged.

Inspect the entire length of the wire for cuts, abrasions, or signs of melting. If damage is found, replace the affected section of wire or the entire run to ensure safety.

Pros and Cons

Pros

  • High flexibility due to Class 5 conductor.
  • Robust PVC insulation offers good protection.
  • Standardized green/yellow color for safety compliance.
  • Compact outer diameter simplifies installation.
  • Meets European fire safety standards (Eca).

Cons

  • Limited to 500V nominal voltage applications.
  • PVC insulation may not be suitable for extreme temperature environments.
  • Specific cross-section (0.5mm²) may not be adequate for all high-power circuits.

Setup, Compatibility & Care

Setup: This wire is designed for professional installation. Ensure that the appropriate tools for stripping and terminating wires are used. Connect the green/yellow conductor to the earth terminal of your system. Verify that the wire's nominal voltage (500V) and cross-section (0.5mm²) are suitable for the intended application and comply with local electrical codes.

Compatibility: Compatible with standard electrical connectors, terminals, and conduit systems designed for wires of this diameter and type. It is suitable for use within the temperature range specified by the EN 50525 standard for H05V2-K cables.

Care: This wire is intended for permanent installation. Avoid excessive bending or kinking during installation. Protect the wire from physical damage, sharp objects, and exposure to chemicals or solvents that could degrade the PVC insulation. Ensure proper ventilation around the cable run if operating near the maximum temperature limits.

Price History

DatePrice
Visit shop