Lapp SC 2.1 UL Installation Wire - 4160205-100 [100 Meters] - White

Lapp SC 2.1 UL 70° xx installation wire, composition conductor class 5 = flexible, nominal conduct...

Best current price£4.26from eBay

Colour

All Offers

16 offers from £4.26 - £75.64

View price history by clicking the chart icon.

eBay2 m LAPP 4160305 Wire
£13.20 delivery
£4.26
Visit shop
Tameson UKLapp Sc 2.1 Ul Installation Wire - 4160144-100 [100 Meters] - Nominal Cross Section Conductor: 0.5 Mm2
Free delivery in 1–3 days
£33.21
Visit shop
Rapid Online - Rapid Electronics Ltd.LAPP 4160105 UL: MTW CSA-HAR Single Core Cable White 22AWG (100m)
Free delivery in 1–3 days
£38.09
Visit shop

Product Information

Full details

The Lapp SC 2.1 UL Installation Wire is designed for electrical installations requiring a flexible, durable, and high-voltage-rated wire. It offers a key benefit of reliable performance in demanding environments due to its PVC insulation and class 5 flexible conductor. A potential caveat is its specific nominal conductor diameter and cross-section, which must match project requirements. Key features include its 750V nominal voltage rating, wide processing temperature range (-40°C to +90°C), and flexible conductor for ease of installation.

All features

ColourWhite
Model Part Number4160205
BrandLAPP

Extended Product Information

FAQs

What does 'UL 70°' refer to?

'UL 70°' indicates that the wire is recognized by Underwriters Laboratories (UL) and is rated for use up to a temperature of 70°C. However, the product description also notes a processing and operating temperature range of -40°C to +90°C, so always refer to the full specifications for your application.

Can this wire be used for outdoor applications?

The PVC insulation offers some protection, but it is generally recommended for use in dry or protected environments. For prolonged outdoor exposure or harsh weather conditions, consult the product specifications or consider wires with enhanced UV or weather resistance.

What is the difference between nominal conductor diameter and cross-section?

The nominal conductor diameter (0.98mm) is the average diameter of a single conductor strand, while the nominal conductor cross-section (0.75mm²) is the total cross-sectional area of all conductor strands combined. This total area determines the wire's current-carrying capacity.

Is this wire suitable for mains power supply?

With a 750V rating, it is suitable for many power supply applications, but you must ensure the 0.75mm² cross-section is adequate for the current demands of your specific application and complies with all relevant electrical codes.

How many meters of wire are included in the Lapp SC 2.1 UL 4160205 model?

The product title indicates '100 Meters' for the Lapp SC 2.1 UL 4160205 variant.

What are the color options available for the SC 2.1 UL Installation Wire?

This specific variant (4160205) is white. Other color options like Grey, Red, Blue, Violet, and Green/Yellow are available in different LAPP SC 2.1 UL variants.

Troubleshooting

Wire does not conduct electricity

Verify that the wire is correctly terminated at both ends and that the connection is secure. Check for breaks in the conductor strands or damage to the insulation that may have compromised the connection.

Intermittent connection or poor signal

Ensure that all connections are tight and properly crimped or screwed. Loose connections are a common cause of intermittent issues. Inspect for corrosion on the conductor strands or terminal points.

Insulation damage during stripping

Use a wire stripper with adjustable depth settings or a stripper specifically designed for fine-stranded wire. Practice slow, controlled movements to avoid cutting into the conductor.

Wire is too stiff for the application

While this wire is designed for flexibility, extremely tight bends may still be challenging. Ensure the installation path allows for the minimum bend radius. For applications requiring more flexibility, consider wires with a higher conductor class.

Pros and Cons

Pros

  • High nominal voltage rating (750V) for broad application.
  • Flexible conductor design simplifies installation in confined spaces.
  • Durable PVC insulation provides good chemical and abrasion resistance.
  • Wide operating temperature range accommodates various environments.
  • Clear color coding (white) aids in identification and organization.
  • Compliant with UL standards for safety and reliability.

Cons

  • Specific 0.75mm² cross-section may not be suitable for all high-current applications.
  • PVC insulation may have limitations in extremely high-temperature environments compared to specialized materials.
  • Requires careful stripping of PVC insulation to avoid damaging the fine strands.
  • Color options are limited in this specific variant (white).

Setup, Compatibility & Care

Setup:

  1. Ensure the wire's voltage and current ratings are appropriate for your application.
  2. Use appropriate tools for stripping the 2.9mm outer diameter PVC insulation, being careful not to nick the fine conductor strands.
  3. Terminate using compatible connectors, crimp terminals, or screw terminals designed for 0.75mm² conductors.

Compatibility:

  • This wire is compatible with standard electrical installation methods and connectors suitable for 0.75mm² stranded conductors.
  • It is designed for use within its specified voltage (750V) and temperature (-40°C to +90°C) limits.
  • Check local electrical codes and regulations for specific installation requirements.

Care:

  • Keep the wire clean and free from excessive dust or debris, especially around terminations.
  • Avoid exposing the wire to solvents or chemicals that can degrade PVC insulation.
  • Periodically inspect visible sections of the wire for any signs of physical damage or degradation, particularly in harsh environments.

Price History