Lapp H05V2-K Installation Wire - 4515071-100 [100 Meters]
![Lapp H05V2-K Installation Wire - 4515071-100 [100 Meters]](https://shopping-cdn.redbrainapis.com/v/088efc5799137497eeb31c818118eb41f70c3a1939c75504b2b34146335d4bef_500x500.jpeg)
Best current price£27.58from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Lapp Orange H05v2-K Installation Wire - 4515091-100 [100 Meters]
Visit shop![Lapp H05V2-K Installation Wire - 4515071-100 [100 Meters]](https://shopping-cdn.redbrainapis.com/v/088efc5799137497eeb31c818118eb41f70c3a1939c75504b2b34146335d4bef_500x500.jpeg)
Best current price£27.58from Tameson UK
Shopping.co.uk recommended and popular offers
Lapp Orange H05v2-K Installation Wire - 4515091-100 [100 Meters]
Visit shop10 offers from £27.58 - £29.82
View price history by clicking the chart icon.
This Lapp H05V2-K 90° installation wire is designed for electrical installations requiring flexibility and a 90°C temperature rating. It offers a reliable conductor insulation with a nominal cross-section of 0.5mm² and a nominal voltage of 500V, making it suitable for various internal wiring applications. A key benefit is its flexibility, facilitating easier routing in confined spaces. However, it's important to note that it has a CPR Euro fire class of 'eca', indicating its specific fire performance characteristics.
| Model Part Number | 4515071 |
|---|---|
| Brand | LAPP |
The Lapp H05V2-K 90° wire has a maximum operating temperature of 90°C.
This wire is designed for internal installation and is not rated for outdoor use. Its CPR fire class is 'eca', which may not meet stringent outdoor environmental requirements.
Class 5 conductor refers to a highly flexible conductor made of many fine strands of copper, making the wire easy to bend and route.
The nominal conductor diameter is 0.8mm.
The nominal conductor cross-section is 0.5mm².
The outer diameter of the wire is 2.5mm.
This wire has a nominal voltage rating of 500V.
Ensure the wire is at room temperature (above 5°C). The Class 5 conductor is flexible but may become less pliable in very cold conditions.
Verify that the conductor has been properly stripped and fully inserted into the terminal. Ensure the terminal is securely tightened and compatible with the 0.5mm² wire gauge.
Use appropriate tools for stripping and bending. Avoid sharp tools or excessive force that could nick or cut the insulation. Ensure no sharp edges are present in the installation path.
Setup: This wire is designed for fixed installation. Ensure proper stripping of the PVC insulation to expose the conductor for termination. Use appropriate crimping tools or screw terminals designed for the 0.5mm² conductor size.
Compatibility: Compatible with standard electrical installation practices and connectors suitable for 0.5mm² flexible conductors. Ensure the system's nominal voltage does not exceed 500V.
Care: Due to its PVC insulation, avoid prolonged exposure to extreme temperatures outside the specified processing range (5 - 70°C) and harsh chemicals that can degrade PVC. Keep the wire clean and free from dust and debris to prevent potential insulation damage over time. Regular visual inspection of the insulation for any signs of wear or damage is recommended.