Bg 10 Way Dual Rcd Metal Consumer Unit With 10 X Mcbs - British General - CFUDP18610
This range of all metal consumer units offer a flexible solution for the 17th Edition Wiring Regul...This range of all metal consumer units offer a flexible solution for the 17th Edition Wiring Regulation Amendment 3. Available in a number of sizes from 6 way to 16 way, these consumer units will suit most applications. Each unit has an integrated spirit level, aiding installing without additional tools. Supplied with 100A Main Switch, 80A & 63A RCDs. Each unit is supplied with busbar, label sheet, 2 cover blanks and instructions. These consumer units are fully populated, complete with MCBs. The terminal and busbar design provide maximum flexibility for combination of protected or unprotected circuits. A range of RCBOs and additional BG control devices can be fitted into the consumer units. Features: Dual RCD Consumer Unit Fully populated with MCBs Manufactured from steel Amendment 3 compliant Curved profile Complete with M20 and M32 knockouts Consumer unit glands are also available Supplied complete with label sheet and accessories
This guide is for electricians and homeowners needing to understand and use the British General 10 Way Dual RCD Metal Consumer Unit (CFUDP18610). The key benefit is providing a safe and compliant electrical distribution system. A key consideration is ensuring proper installation by a qualified electrician.
All features
Model Part Number
CFUDP18610
Brand
British General
Extended Product Information
FAQs
What is an RCD?
An RCD (Residual Current Device) is a safety device designed to quickly disconnect the power if it detects an imbalance in the electrical circuit, protecting against electric shock.
What does Amendment 3 compliance mean?
Amendment 3 to the 17th Edition Wiring Regulations sets out updated safety standards for electrical installations, including enhanced protection against fire and electric shock.
Can I install this unit myself?
No, this unit must be installed by a qualified electrician to ensure safety and compliance with regulations.
What size cables should I use?
The cable size depends on the circuit's current rating and length. Consult with a qualified electrician to determine the appropriate cable size for each circuit.
How do I test the RCDs?
There is a test button on each RCD. Pressing this button should trip the RCD, confirming it's working correctly. Test them regularly.
What accessories can I add?
You can add RCBOs and other BG control devices. Ensure they are compatible with the consumer unit's specifications.
What if a circuit keeps tripping?
If a circuit keeps tripping, there's likely a fault. Unplug appliances on that circuit, reset the MCB, and then plug them back in one by one to identify the faulty appliance. If the MCB trips again with nothing plugged in, call an electrician.
Troubleshooting
Unit not powering on.
Check the main switch and ensure the incoming supply is connected correctly. Verify that the RCDs are not tripped.
Individual circuits not working.
Check the corresponding MCB for the faulty circuit. If tripped, reset it. If it trips again, investigate for a fault in the circuit.
RCD tripping frequently.
Identify the circuit causing the RCD to trip, and inspect the appliances/wiring for faults. If necessary, consult an electrician.
Pros and Cons
Pros
Ready to use with pre-installed MCBs, reducing installation time.
Dual RCD design enhances safety.
Compliant with Amendment 3 wiring regulations.
Durable steel construction ensures long-term reliability.
Integrated spirit level simplifies the installation process.
Cons
Requires professional electrical installation.
Additional RCBOs and control devices are required for more complex circuits.
Knockouts may require additional tools for cable entry.
Setup, Compatibility & Care
Setup
Professional Installation: This unit must be installed by a qualified electrician.
Mounting: Use appropriate fixings to secure the unit to the wall, ensuring it's level using the integrated spirit level.
Cable Entry: Use the M20 and M32 knockouts for cable entry, ensuring proper cable glands are fitted.
Wiring: Connect the incoming supply to the main switch, and wire the outgoing circuits to the MCBs and RCDs, following the wiring diagram.
Testing: After installation, thoroughly test the circuits to ensure they are functioning correctly.
Compatibility
Wiring Regulations: Compatible with installations adhering to the 17th Edition Wiring Regulations Amendment 3.
Accessories: Compatible with a range of RCBOs and additional BG control devices.
Care
Regular Inspection: Have the unit inspected regularly by a qualified electrician.
Cleaning: Keep the unit clean and free from dust and debris.
Maintenance: Perform regular checks to ensure all connections are secure and that the unit is operating correctly.