Siemens 6ES72111AE400XB0 S7-1200 PLC CPU - Compact CPU - 6 Digital Inputs - 4 Digital Outputs - 2 Analogue Inputs

This Siemens SIMATIC S7-1200 Series PLC CPU features a compact design and operates with a supply v...

Best current price£148.26from eBay

All Offers

23 offers from £148.26 - £768.61

View price history by clicking the chart icon.

eBayNew Siemens 6ES7211-1HE40-0XB0 [24 Months Warranty]
£28.01 delivery
£148.26
Visit shop
Rapid Online - Rapid Electronics Ltd.Siemens 6ES72111BE400XB0 Alpha unit wall-mounted IP55 RAL 9016
Free delivery in 1–3 days
£248.24
Visit shop
Tameson UKSiemens S7-1200 Cpu 1211C Compact Plc Controller - 6Es72111ae400xb0
Free delivery in 1–3 days
£288.28
Visit shop

Used Offers

7 offers from £164.00 - £657.32

View price history by clicking the chart icon.

eBaySiemens 6ES7 211-1AE40-0XB0
£13.00 delivery
£164.00
Visit shop

Product Information

Full details

This guide is for automation engineers and technicians seeking a compact, versatile PLC for small to medium-sized control tasks. The Siemens SIMATIC S7-1200 CPU 1211C offers robust performance with integrated digital and analog I/O, extensive communication capabilities, and a small footprint, making it ideal for machine control and automation projects. A key caveat is its DC power requirement, necessitating a compatible power supply.

All features

BrandSiemens

Extended Product Information

FAQs

What type of power supply is required for the 6ES7211-1AE40-0XB0?

This CPU module requires a DC power supply operating within the voltage range of 20.4 to 28.8V DC.

How many digital and analog inputs/outputs does this CPU have?

It features 6 digital inputs (2 of which can be configured as analog inputs) and 4 digital outputs (transistor type).

What programming software is used with this PLC?

This Siemens SIMATIC S7-1200 CPU is programmed using Siemens TIA Portal software.

Can this PLC be used in hazardous environments?

Yes, this module is ATEX certified for gas explosion safety (Category 3G), making it suitable for certain hazardous environments.

What are the physical dimensions of the module?

The dimensions are approximately 90mm in width, 100mm in height, and 75mm in depth.

Does the CPU have integrated communication ports?

Yes, it supports multiple communication protocols including TCP/IP, PROFIBUS, ASI, MODBUS, and PROFINET IO, typically accessed via an integrated Ethernet port or expansion modules.

What is the program memory capacity?

The CPU module has 50kByte of RAM for program and data storage.

Troubleshooting

CPU not powering on

Verify the DC power supply is connected correctly and providing voltage within the 20.4-28.8V DC range. Check all power wiring connections for security.

Program download fails

Ensure the programming cable is connected securely and the correct communication interface (e.g., Ethernet) is selected in TIA Portal. Check that the CPU is in the correct mode for download (e.g., STOP mode).

Digital/Analog I/O not functioning

Double-check wiring to the I/O terminals. Verify that field devices are providing correct signals and that the I/O configuration in the program matches the actual wiring.

Communication errors

Confirm network cable connections. Verify IP addresses and subnet masks (if applicable) are configured correctly in both the PLC and the network. Check that the communication protocol is properly set up in the PLC program.

Pros and Cons

Pros

  • Compact and space-saving design
  • Integrated digital and analog I/O reduces hardware costs
  • Wide range of supported communication protocols for flexible integration
  • Fast processing speed for demanding applications
  • ATEX certification for use in potentially explosive atmospheres

Cons

  • Requires a separate DC power supply (20.4-28.8V DC)
  • Limited onboard I/O count for very large-scale applications
  • Program/data memory might be insufficient for extremely complex programs

Setup, Compatibility & Care

Setup:

  1. Power Connection: Connect a DC power supply (20.4-28.8V DC) to the designated power terminals on the CPU module.
  2. Mounting: Mount the CPU module onto a standard DIN rail, wall, or use the front build-in option as required by your enclosure.
  3. Wiring: Connect field devices (sensors, actuators) to the onboard digital and analog input/output terminals.
  4. Programming: Connect to a programming device (PC) via Ethernet (for PROFINET/TCP/IP) or other supported interfaces and use Siemens TIA Portal software to develop and download your control program.

Compatibility:

  • Power Supply: Requires a stable DC power supply within the 20.4 to 28.8V DC range.
  • Programming Software: Compatible with Siemens TIA Portal. Ensure you are using a compatible version for this CPU model.
  • Communication Networks: Integrates with Ethernet-based networks (PROFINET, TCP/IP), PROFIBUS, ASI, and MODBUS.

Care:

  • Environment: Operate within specified temperature and humidity ranges. Avoid excessive dust, vibration, and corrosive atmospheres.
  • Cleaning: Disconnect power before cleaning. Use a dry, lint-free cloth to wipe down the exterior. Avoid liquids and solvents.