Intaball Compression Ball Valve - Yellow Lever (Gas) 15mm - Altecnic

The Intaball gas range of full bore lever operation ball valves is ideal for general gas purpose a...

Best current price£8.80from Travis Perkins

One Offer

1 offer from £8.80

View price history by clicking the chart icon.

Travis PerkinsAltecnic AI-331115 Intaball Compression Ball Valve Yellow Lever (Gas) 15mm
£30.00 delivery
£8.80
Visit shop

Product Information

Full details

This guide is for plumbers and gas engineers working with domestic gas installations. The Altecnic Intaball 15mm gas ball valve offers reliable shut-off for gas lines with its full bore design and durable construction. A key consideration is its specific use for gas applications only.

All features

Model Part NumberAI-331115
BrandAltecnic

Extended Product Information

FAQs

What type of gas is this valve suitable for?

This valve is designed for town gas and natural gas applications.

What does 'full bore' mean?

Full bore means the internal diameter of the valve is the same as the internal diameter of the pipe when the valve is fully open, allowing for maximum flow and minimal pressure drop.

Is this valve suitable for water systems?

No, this specific Intaball valve is designed and certified for gas applications only, indicated by the yellow handle.

What is the maximum operating temperature?

The maximum working temperature for this valve is 95°C.

How do I ensure a gas-tight connection?

Ensure pipe ends are clean and free from burrs. Insert the pipe fully into the compression fitting and tighten the compression nut securely according to standard practices for gas fittings. Always test for leaks after installation.

What standards does this valve meet?

The valve is designed and built to meet the requirements of BS EN 331:1998 and AI 2010.

What does the yellow handle signify?

The yellow handle is a visual indicator that the valve is specifically intended for gas use.

Troubleshooting

Valve is stiff to operate.

Ensure pipework is aligned correctly and not putting undue stress on the valve body. Check that compression nuts are not overtightened. If the problem persists, the valve may require professional inspection.

Leak detected at the compression fittings.

Turn off the gas supply immediately. Inspect the pipe end for damage or burrs. Ensure the olive is correctly seated and re-tighten the compression nut. If the leak persists, replace the olive and re-make the connection, or seek professional assistance.

Low gas flow when valve is open.

Verify the valve is fully open. Check for any blockages in the pipework upstream or downstream of the valve. Ensure the valve is the correct size for the gas line requirements.

Pros and Cons

Pros

  • Compliant with relevant gas safety standards.
  • Full bore design ensures high flow and low pressure drop.
  • Durable construction with hard chrome-plated ball and PTFE seals.
  • Clear identification for gas use with a yellow handle.
  • Secure compression fittings.

Cons

  • Primarily designed for gas; not suitable for other fluid types.
  • Maximum working temperature of 95°C may limit use in some niche applications.
  • Requires proper installation to ensure gas-tight connections.

Setup, Compatibility & Care

Setup: The Intaball valve features compression ends designed to BS EN 1252-4 standards. Ensure the pipe ends are clean, free from burrs, and properly inserted into the compression fittings. Tighten the compression nuts securely according to standard plumbing practices for gas compression fittings. It is essential that all gas installations are carried out by qualified personnel and tested for leaks according to local regulations.

Compatibility: This valve is specifically designed for use with town gas and natural gas. It is suitable for applications up to a maximum working temperature of 95°C. Ensure the pipe material is compatible with the valve's compression fittings.

Care: Minimal maintenance is required for this valve. Keep the external surfaces clean and free from dust or debris. Periodically check the tightness of the compression fittings. In the unlikely event of a leak, the valve should be shut off immediately, and the connection re-tightened or re-made by a qualified engineer.

Price History

DatePrice