nVent ERIFLEX Distribution Block - 563990

Best current price£96.05from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Nvent Eriflex Distribution Terminal Block - 563990
Visit shop
Best current price£96.05from Tameson UK
Shopping.co.uk recommended and popular offers
Nvent Eriflex Distribution Terminal Block - 563990
Visit shop2 offers from £96.05 - £161.00
View price history by clicking the chart icon.
The nVent ERIFLEX Distribution Block (MPN: 563990) is designed for electrical contractors and panel builders needing a reliable method to distribute power. Its key benefit is high current capacity (160A) with versatile terminal options, allowing for efficient and safe wiring. A potential caveat is its fixed pole configuration, requiring careful planning for specific system designs.
| Model Part Number | 563990 |
|---|---|
| Brand | nVent ERIFLEX |
The nVent ERIFLEX Distribution Block (563990) has a maximum current rating of 160A.
The input terminal accepts conductors from 10mm² to 50mm². The output terminals accept 3 conductors from 10mm² to 35mm² and 8 conductors from 2.5mm² to 16mm².
This distribution block has 4 poles.
Yes, this distribution block is designed for standard DIN rail mounting, facilitating easy installation in electrical panels.
This block is designed for use with copper conductors.
While standard screwdrivers are used for terminals, a torque wrench is highly recommended to ensure proper tightness, and specialized tools may be needed for crimping or preparing larger gauge conductors.
This block is designed for use within electrical enclosures and panels. Its suitability for outdoor use depends on the enclosure's NEMA/IP rating and environmental conditions.
Check if terminal screws are tightened to the correct torque. Ensure conductors are properly seated and of the correct gauge for the terminal. Verify the total current draw does not exceed the 160A rating.
Ensure the conductor is stripped to the correct length and inserted fully into the terminal. Re-tighten the terminal screw using a torque wrench to the specified value. Check conductor for damage or corrosion.
Confirm you are using the correct input or output terminal designed for that wire gauge (e.g., 50mm² input). Ensure the conductor end is clean, square, and free of deformation.
Immediately de-energize the circuit. Inspect for loose connections, undersized conductors, or sustained current draw exceeding the 160A rating. Replace the damaged block and address the root cause.
Setup:
Compatibility:
Care: