Finder Timer Relay - 83 Series - 83.91.0.240.0000

Industrial modular timer relay featuring asymmetrical flasher functionality in a compact 22.5mm wi...

Best current price£73.49from Tameson UK

All Offers

4 offers from £73.49 - £218.15

View price history by clicking the chart icon.

Tameson UKFinder 83.91 Industrial Timer Relay 16A 24-240V Ac/Dc - 83.91.0.240.0000
Free delivery in 1–3 days
£73.49
Visit shop
eBay1P 16A 24-240V AC/DC Timing Relay 83.91.0.240.0000
£13.20 delivery
£153.62
Visit shop
Blueperry agriculture (UK)Finder Silver Timer Relay 839102400000
Free delivery in 1–3 days
£197.60
Visit shop

Product Information

Full details

This Finder Timer Relay (83 Series, MPN 83.91.0.240.0000) is designed for industrial applications requiring precise timing and switching. Its key benefit is the flexible multi-voltage input and asymmetrical flasher functionality, making it suitable for a wide range of power systems. A potential consideration is its specialized nature, requiring an understanding of industrial timer relays for optimal use.

All features

Series83 Series
Model Part Number83.91.0.240.0000
BrandFinder

Extended Product Information

FAQs

What is the function of the asymmetrical flasher?

The asymmetrical flasher provides a timed output where the ON time and OFF time are different and independently adjustable, used for specific signaling or pulsing applications.

Can this timer be used with 12V DC systems?

No, the minimum input voltage is 24V AC/DC. It is not designed for 12V systems.

How do I set the time delay?

Time delays are set using the rotary switches on the front of the unit. Refer to the product's technical documentation or manual for the specific mapping of switch positions to time ranges and durations.

What is the maximum current the output contacts can handle?

The single changeover (SPDT) contacts are rated for a maximum of 16A at 250VAC.

Does the timer need a separate power supply for its internal functions?

No, the timer operates and is powered by the same 24-240V AC/DC input supply connected to its input terminals.

What does the 22.5mm width refer to?

This refers to the physical width of the relay module, which is designed to fit compactly onto a standard 35mm DIN rail, making it suitable for control panels with limited space.

Is this timer suitable for outdoor use?

The product is designed for industrial applications and typically requires installation within a control panel or enclosure to protect it from environmental factors like moisture, dust, and extreme temperatures.

Troubleshooting

Relay does not activate upon power-up.

Verify that the input voltage is correctly applied to the designated terminals and is within the 24-240V AC/DC range. Check for loose wire connections.

Output contacts do not switch.

Ensure the time delay setting is appropriate for the desired operation. Confirm that the load connected to the output terminals is within the 16A/250VAC rating. Check if the input voltage is stable.

Timing is inaccurate or inconsistent.

Check for voltage fluctuations in the power supply. Ensure the ambient temperature is within the operating range. Verify that the time setting is correctly configured.

Relay hums loudly.

This may indicate a voltage mismatch or a failing internal component. Ensure the input voltage is stable and within the specified range. If the issue persists, consider replacing the unit.

Pros and Cons

Pros

  • Versatile multi-voltage input simplifies integration into various electrical systems.
  • Compact size is ideal for space-constrained industrial control panels.
  • Wide time range allows for precise control over diverse operational cycles.
  • Robust 16A contact rating handles significant electrical loads.
  • Asymmetrical flasher function offers specialized output for specific applications.

Cons

  • Requires basic understanding of industrial timer relay functions for setup.
  • Single SPDT contact may limit complex switching scenarios.
  • Asymmetrical flasher is a specific function; may not be needed for all applications.
  • Only one output contact limits the number of circuits that can be controlled directly.

Setup, Compatibility & Care

Setup:

  1. Mount the timer relay onto a standard 35mm DIN rail.
  2. Connect the power supply to the designated input terminals (24-240V AC/DC). Ensure the voltage matches the supply.
  3. Wire the control circuit to the SPDT output terminals (COM, NO, NC) according to your application's needs.
  4. Set the desired time delay using the rotary switches on the front of the unit. Consult the product manual for precise setting configurations.

Compatibility:

  • Input Voltage: Compatible with 24-240V AC or DC power sources.
  • Contact Rating: Suitable for loads up to 16A at 250VAC. Ensure the connected load does not exceed these limits.

Care:

  • Keep the unit clean and free from dust and moisture.
  • Avoid operating in environments with excessive vibration or extreme temperatures.
  • Regularly check electrical connections for tightness.