Festo Soft Start Valve - G1/8''

Best current price£68.86from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Festo Soft Start Valve G1/4'' 4-14Bar 2000L/Min - 529532
Visit shop
Best current price£68.86from Tameson UK
Shopping.co.uk recommended and popular offers
Festo Soft Start Valve G1/4'' 4-14Bar 2000L/Min - 529532
Visit shop3 offers from £68.86 - £68.90
View price history by clicking the chart icon.
2 offers from £15.50 - £23.24
View price history by clicking the chart icon.
This Festo Soft Start Valve (MPN: MS4-DL-1/8) is designed for industrial pneumatic systems requiring controlled pressurization. It's ideal for users who need to prevent sudden system shocks and wear on components by gradually building up pressure. A key benefit is enhanced safety and extended equipment lifespan. However, it requires a minimum operating pressure of 4 bar to function effectively.
| Model Part Number | MS4-DL-1/8 |
|---|---|
| Brand | Festo |
The maximum operating pressure for the Festo Soft Start Valve MS4-DL-1/8 is 14 bar, with a maximum nominal operating pressure of 8 bar specified in some technical documents.
The valve requires a minimum operating pressure of 4 bar to function correctly.
While the valve is designed for compressed air, using lubricated air is generally acceptable within standard industrial practices. However, excessively oily air or contaminants can affect long-term performance and may require more frequent maintenance.
The pressure build-up time is adjusted using a control knob on the valve. Turning the knob in one direction increases the time, and turning it in the opposite direction decreases it. Specific directions are usually indicated on the valve itself.
The standard nominal flow rate for this valve is 1000 l/min.
The valve has a compact width of 40 mm, making it suitable for space-constrained applications.
The pneumatic connection thread size is G1/8.
Check if the inlet pressure is above the minimum 4 bar. Ensure the control signal is properly applied to the actuation port. Verify that the pressure build-up time is not set to its minimum or that the valve is not bypassed.
Adjust the pressure build-up time control knob. Clockwise typically increases the build-up time, while counter-clockwise decreases it. Refer to the specific valve markings for adjustment direction.
Inspect all pneumatic connections for tightness. Check the valve body for any visible damage. If leaks persist, the internal seals may be compromised, and the valve might require replacement.
Confirm that the pneumatic control signal is being supplied to the actuation port at the correct pressure. Ensure the control line is not kinked or blocked.
Setup:
Compatibility:
Care: