Eaton FAZ Circuit Breaker - C1A - 1 pole




Best current price£24.83from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Eaton Industries Faz Circuit Breaker - 278546
Visit shop



Best current price£24.83from Tameson UK
Shopping.co.uk recommended and popular offers
Eaton Industries Faz Circuit Breaker - 278546
Visit shop4 offers from £24.83 - £77.04
View price history by clicking the chart icon.
This Eaton Moeller series xEffect FAZ Miniature Circuit Breaker (MCB) is designed for commercial and industrial applications requiring reliable overcurrent protection. It offers a 10 kA breaking capacity and a Type C tripping characteristic, suitable for loads with moderate inrush currents, providing a key benefit of robust protection for sensitive equipment. A potential caveat is its AC and DC voltage limitations, requiring careful consideration for specific power systems.
| Series | xEffect FAZ |
|---|---|
| Model Part Number | 278546 |
| Brand | EATON INDUSTRIES |
A Type C tripping characteristic is designed to withstand moderate inrush currents (typically 5 to 10 times the rated current) that occur briefly when certain types of equipment, like motors or fluorescent lights, are switched on. This prevents nuisance tripping while still providing protection against short circuits.
The Eaton FAZ-C1/1 circuit breaker has a breaking capacity of 10 kA (kiloamperes), meaning it can safely interrupt fault currents up to this level.
Yes, it can be used for DC circuits, but only up to a maximum voltage of 48V DC.
The breaker has a width of 17.7mm and is designed for mounting on a standard 35mm DIN rail.
The connectable conductor cross-section for both multi-wired and solid-core conductors ranges from 1mm² to 25mm².
IP20 indicates that the device is protected against solid objects greater than 12.5mm (like a finger) but offers no protection against water. It should be installed in an enclosure to prevent contact and dust ingress.
The breaker can operate reliably in ambient temperatures ranging from -25°C to 75°C.
Verify the connected load does not exceed the 1A rated current. Check for short circuits in the downstream wiring. Ensure the tripping characteristic (Type C) is appropriate for the connected equipment's inrush current.
Ensure the breaker is correctly wired and energized. Check for loose connections. If the issue persists, the breaker may be faulty and requires replacement.
A slight warmth may be normal. However, if it is excessively hot, check conductor connections for tightness and ensure conductors are within the specified cross-section range (1-25mm²). Overloading or a failing breaker could also be the cause.
Setup:
Compatibility:
Care: