Wylex Miniature Circuit Breaker - NHXLB40 - 40A Type B

Wylex 40A NHXL MCB - B CURVE (2018), 10. Wylex NHXLB40 Miniature Circuit Breaker MCB 6kA Type B - ...

Best current price£7.90from OnBuy.com

All Offers

8 offers from £7.90 - £22.15

View price history by clicking the chart icon.

OnBuy.comWylex Nhxlb40 Miniature Circuit Breaker Mcb 6Ka Type B - 40 Amp 5013601089126
Free delivery in 1–3 days
£7.90
Visit shop
eBayWylex NHXLB40 Miniature Circuit Breaker MCB 6kA Type B - 40 Amp
Free delivery in 1–3 days
£8.95
Visit shop
B&QB&Q - 40A Mcbs Type B Single Pole Miniature Circuit Breaker-40A
Free delivery in 1–3 days
£9.95
Visit shop

Used Offer

1 offer from £7.75

View price history by clicking the chart icon.

eBayWylex NHXLB Range - NHXLB40 - 40a Type B Single Pole MCB Latest Style Used
Free delivery in 1–3 days
£7.75
Visit shop

Product Information

Full details

The Wylex NHXLB40 is a 40A Type B Miniature Circuit Breaker (MCB) designed for residential and commercial electrical installations. It offers reliable overcurrent protection, tripping swiftly for moderate overloads and slower for short circuits, making it suitable for circuits with predominantly inductive loads or equipment with high inrush currents. A key benefit is its adherence to BS EN 60898-1 standards, ensuring safety and performance. However, its Type B tripping characteristic means it may not be ideal for all types of equipment, particularly those with very high starting currents.

All features

Model Part NumberNHXLB40
BrandWylex

Extended Product Information

FAQs

What does 'Type B' mean for this MCB?

A Type B MCB is designed to trip between 3 to 5 times its rated current. This makes it suitable for circuits with primarily resistive loads or equipment with low inrush current. It is less suitable for circuits with high inductive loads or large motors that draw significant current on startup.

What is the 6kA rating?

The 6kA rating refers to the MCB's ability to safely interrupt a short-circuit fault current of up to 6000 Amperes. This is a standard safety measure for typical domestic and commercial installations.

Can I install this MCB myself?

No, installation of circuit breakers requires specialized knowledge and adherence to safety regulations. It must be installed by a qualified electrician.

What is the difference between Type B, Type C, and Type D MCBs?

Type B trips at 3-5x rated current (for resistive loads), Type C trips at 5-10x (for inductive loads like motors), and Type D trips at 10-20x (for high inrush currents like transformers or welding equipment). The NHXLB40 is Type B.

How do I know if this MCB is right for my circuit?

This Type B MCB is suitable for circuits with low inrush currents, such as lighting, socket outlets for general use, and small appliances. Consult with a qualified electrician if you are unsure about the load characteristics of your circuit.

Where is this MCB manufactured?

The product description indicates it was manufactured to BS EN 60898-1 standards, with a mention of '2018' which likely refers to a production year or standard revision.

Troubleshooting

MCB trips frequently under normal load

This could indicate an overload condition or a faulty appliance. Check the total load on the circuit. If the load is within limits, test individual appliances or consider upgrading the circuit capacity or MCB type if high inrush currents are expected.

MCB does not trip when a fault occurs

This is a serious safety concern. Do not use the circuit. Immediately contact a qualified electrician to inspect and replace the MCB and investigate the fault.

MCB is warm to the touch during operation

Slight warmth can be normal under load. However, if it is excessively hot, turn off the circuit and have a qualified electrician inspect the connections and the MCB itself for potential issues.

Pros and Cons

Pros

  • Offers reliable overcurrent protection for standard electrical circuits.
  • BS EN 60898-1 compliant, ensuring adherence to safety standards.
  • 6kA breaking capacity provides adequate protection against short circuits.
  • Durable construction from a trusted brand.
  • Type B curve is suitable for many common household appliances.

Cons

  • Type B tripping curve may be too sensitive for equipment with high inrush currents (e.g., large motors).
  • Single pole design is not suitable for all installation types.
  • Specific manufacturing date (2018 mentioned) might be a consideration for very old installations requiring exact replacements.
  • Requires professional installation by a qualified electrician.

Setup, Compatibility & Care

Setup: The Wylex NHXLB40 is designed for installation within standard consumer units or distribution boards. It requires connection to a compatible busbar system and appropriate wiring for the circuit it is protecting. Installation must be performed by a qualified electrician to ensure safety and compliance with electrical regulations.

Compatibility: This MCB is designed to be compatible with UK and European standard consumer units and busbar systems. It adheres to BS EN 60898-1 standards. Ensure your existing or new consumer unit has sufficient space and the correct busbar type for installation.

Care: As a protective device, the MCB requires minimal user care. However, periodic visual inspection for dust or debris accumulation around the unit is recommended. In environments prone to dust, ensure ventilation is not obstructed. For maintenance or inspection, always ensure the main power supply to the consumer unit is isolated by a qualified person.

Price History

DatePrice
Visit shop