Schneider Electric C120N Circuit Breaker - 3P, 125A, 10kA

Low voltage miniature circuit breaker (MCB) with 3-pole protection and C-characteristic trip curve...

Best current price£169.95from eBay

All Offers

11 offers from £169.95 - £425.30

View price history by clicking the chart icon.

eBaySCHNEIDER 80 AMP B CURVE 15kA TRIPLE POLE MCB CIRCUIT BREAKER C120H A9N18424
Free delivery in 1–3 days
£169.95
Visit shop
Tameson UKSchneider Electric Circuit Breaker - A9n18365
Free delivery in 1–3 days
£211.62
Visit shop

Used Offer

1 offer from £119.95

View price history by clicking the chart icon.

eBaySCHNEIDER 100 AMP CURVE C 15kA TRIPLE POLE MCB CIRCUIT BREAKER C120H SS09285
Free delivery in 1–3 days
£119.95
Visit shop

Product Information

Full details

This Schneider Electric C120N is a three-pole, low-voltage miniature circuit breaker designed for robust protection in industrial and domestic applications. It offers reliable overcurrent protection with a C-characteristic trip curve and a substantial 10kA breaking capacity, safeguarding circuits from faults. While it provides dual compliance for broad usability, users should be aware of its specific voltage and current ratings to ensure appropriate application.

All features

SeriesC120N
Model Part NumberA9N18369
BrandSchneider Electric

Extended Product Information

FAQs

What is the difference between Type C and Type D circuit breakers?

Type C breakers are designed to trip between 5 to 10 times their rated current, suitable for loads with moderate inrush currents like lighting and socket circuits. Type D breakers trip between 10 to 20 times their rated current, designed for high inrush current loads such as large motors or transformers.

What does '10kA breaking capacity' mean?

This indicates the maximum fault current the circuit breaker can safely interrupt without being destroyed. A 10kA (10,000 Amperes) rating at 380-415VAC means it can safely interrupt short circuits up to this level, protecting the downstream circuit and preventing further damage.

Can this breaker be used for DC circuits?

The primary rating is for AC circuits (220/415 VAC). While some IEC standards cover DC applications, this specific model's documentation primarily focuses on AC performance. For DC applications, consult Schneider Electric for specific product recommendations and ratings.

What is the mechanical and electrical lifetime of this breaker?

The breaker has a mechanical lifetime of 20,000 operating cycles (switching on and off) and an electrical lifetime of 5,000 operating cycles under rated load conditions.

How do I determine if my application requires a 3-pole breaker?

A 3-pole breaker is necessary for protecting three-phase electrical systems, ensuring all three phases are disconnected simultaneously during a fault condition to prevent phase imbalance or damage to three-phase equipment.

What is the significance of the IP20 rating?

IP20 means the breaker is protected against solid objects greater than 12.5 mm in diameter (like fingers) and has no protection against water ingress. It should be installed in a dry, protected enclosure.

Where can I find the specific compliance certificates for this model?

Compliance certificates, such as EN/IEC 60947-2 and IEC 60898-1, are typically listed on the product's datasheet or the manufacturer's official website. This model also complies with RoHS directives.

Troubleshooting

Breaker trips frequently

Check for overloaded circuits or short circuits. Verify that the connected load does not exceed the breaker's 125A rating. Ensure the trip curve (Type C) is appropriate for the connected equipment's inrush current. Inspect wiring for loose connections.

Breaker will not reset after tripping

Ensure the fault condition that caused the trip has been resolved. If the fault persists, the breaker may be damaged and require replacement. If it's a persistent trip without an obvious fault, contact a qualified electrician.

Visual indicator does not change state

Manually operate the breaker switch to confirm its mechanical function. If the indicator is stuck or misaligned, the breaker may require replacement. Ensure the breaker is correctly seated on the DIN rail.

Overheating at terminals

Immediately de-energize the circuit. Check and tighten the terminal connections. If signs of melting or significant discoloration are present, the breaker or wiring may be damaged and require professional assessment and replacement.

Pros and Cons

Pros

  • Provides robust three-phase circuit protection.
  • Dual compliance standards (IEC 60898-1, IEC 60947-2) ensure versatility.
  • High breaking capacity (10kA) for significant fault current interruption.
  • Clear visual indicator for ON/OFF status.
  • Designed for standard DIN rail mounting, simplifying installation.

Cons

  • C-characteristic may not be suitable for equipment with very high inrush currents.
  • Requires knowledge of electrical systems for safe installation and operation.
  • Breaking capacity of 10kA might be insufficient for very high fault current environments; higher series (e.g., C120H) may be needed.
  • Primarily designed for AC circuits; specific DC ratings are not detailed in standard specifications.

Setup, Compatibility & Care

Setup:

  1. Ensure the main power supply is de-energized.
  2. Mount the C120N breaker onto a standard 35mm DIN rail by snapping it into place.
  3. Connect the incoming power conductors to the designated terminals (Line/Phase L1, L2, L3).
  4. Connect the outgoing circuit conductors to the corresponding terminals.
  5. Ensure all connections are secure and torqued to the manufacturer's specifications.
  6. Install any necessary auxiliary contacts or accessories as per the installation manual.

Compatibility:

  • This breaker is designed for AC circuits with an input voltage range of 220/415 VAC.
  • It is compatible with systems requiring a C-characteristic trip curve for loads with moderate inrush currents.
  • Ensure the overall system's expected fault current does not exceed the breaker's 10kA breaking capacity.
  • IP20 rating means it is protected against solid objects >12.5mm but offers no water protection; use in dry, protected environments.

Care:

  • Periodically inspect the breaker for any signs of damage, overheating, or loose connections.
  • Keep the breaker clean and free from dust and moisture.
  • Test the breaker's functionality according to local electrical codes and safety standards, typically through manual operation or specialized testing equipment.
  • Avoid operating the breaker with wet hands or in damp conditions.