Festo 5/3 Exhausted Pneumatic Valve Size 1 ISO 5599-1 1200l/min - VL-5/3E-D-1-C

This pneumatic valve is a 5/3 exhausted model with a standard nominal flow rate of 1200 l/min. Des...

Best current price£78.10from Tameson UK

All Offers

10 offers from £78.10 - £198.99

View price history by clicking the chart icon.

Tameson UKFesto 5/3 Exhausted Pneumatic Valve Size 18Mm Iso 15407-1 450L/Min - 546729
Free delivery in 1–3 days
£78.10
Visit shop

Product Information

Full details

This Festo pneumatic valve, model VL-5/3E-D-1-C, is designed for industrial automation professionals seeking reliable and precise pneumatic control. Its key benefit is a high nominal flow rate of 1200 l/min combined with adherence to ISO 5599-1 standards, ensuring broad compatibility. A potential consideration is its specific size 1 sub-base connection, requiring proper system matching.

All features

Model Part NumberVL-5/3E-D-1-C
BrandFesto

Extended Product Information

FAQs

What does '5/3 exhausted' mean for this valve?

It signifies the valve has five ports and three positions. 'Exhausted' means that in the center position, both work ports are connected to exhaust, venting any residual pressure.

Is this valve compatible with non-ISO 5599-1 systems?

While the valve itself performs its function, direct drop-in replacement compatibility is guaranteed only with other ISO 5599-1 compliant systems of Size 1. You may need adapters or modifications for non-standard systems.

What is the maximum operating pressure?

The product description does not specify the maximum operating pressure, but typical industrial pneumatic valves of this type operate up to 10 bar (145 psi). Refer to the official Festo datasheet for precise specifications.

Can this valve be used for vacuum applications?

This valve is designed for standard compressed air applications and is not typically suitable for vacuum generation or control without specific modifications or accessory components.

How do I determine the correct pilot signal pressure?

The required pilot signal pressure depends on the overall system design and the main air supply pressure. Consult the Festo documentation for the valve or system designer for recommended ranges.

What maintenance is required?

The primary maintenance involves ensuring clean, dry compressed air and checking for pneumatic leaks at connections. Internal maintenance is usually not required unless performance degrades significantly.

Troubleshooting

Valve does not shift when pilot signal is applied.

Check the pilot air supply pressure and connection. Ensure the correct port is receiving the pilot signal. Verify the main air supply is within operational range.

Slow actuator movement.

Inspect main air supply lines for restrictions or leaks. Ensure the nominal flow rate of the valve is sufficient for the actuator's demand. Check exhaust ports for blockages.

Pneumatic leaks from the valve body or connections.

Tighten all pneumatic connections. Inspect seals on the sub-base and ports for damage and replace if necessary. Ensure the valve is correctly seated on the sub-base.

Actuator does not fully extend or retract.

Verify the 5/3 port configuration is correctly plumbed for the desired cylinder action. Check for obstructions in the actuator's travel path. Ensure adequate air pressure and flow.

Pros and Cons

Pros

  • High flow rate (1200 l/min) for efficient operation.
  • Standardized ISO 5599-1 design ensures broad compatibility and easy replacement.
  • Robust construction suitable for demanding industrial settings.
  • Pneumatic actuation allows seamless integration into existing systems.
  • 5/3 functionality provides flexible control options.

Cons

  • Specific sub-base size (Size 1) may limit direct replacement in non-standardized systems.
  • Exhausted design might not be suitable for all applications, especially those requiring pressure holding.
  • Requires a pneumatic signal for actuation, necessitating an air supply for control.
  • Requires proper understanding of 5/3 valve logic for optimal use.

Setup, Compatibility & Care

Setup:

  1. Ensure the main air supply is de-energized.
  2. Mount the valve onto a compatible ISO 5599-1 Size 1 sub-base.
  3. Connect pneumatic lines to the appropriate ports on the sub-base, ensuring correct sealing.
  4. Connect pilot air lines for actuation.
  5. Verify all connections are secure before restoring air pressure.

Compatibility:

  • This valve is designed to be compatible with other components adhering to the ISO 5599-1 standard, specifically Size 1.
  • Requires a pneumatic control signal for actuation.
  • Operates with standard industrial compressed air.

Care:

  • Regularly inspect pneumatic connections for leaks.
  • Ensure the compressed air supply is clean and dry to prevent internal wear.
  • Avoid exposure to excessive moisture, dust, or corrosive substances.

Price History

DatePrice
Visit shop