Timeguard Valiance+ Double-Gang Metal RCD Protected Switched Socket - RCD07MAVN

The Timeguard Valiance+ RCD07MAVN is a durable double-gang metal-clad switched socket featuring in...

Best current price£29.99from eBay

All Offers

2 offers from £29.99 - £37.04

View price history by clicking the chart icon.

eBayTimeguard RCD07MAVN RCD Protected Double Gang Metal Switched Socket - Active
Free delivery in 1–3 days
£29.99
Visit shop

Product Information

Full details

The Timeguard Valiance+ RCD07MAVN is designed for homeowners and contractors seeking enhanced electrical safety in demanding environments like garages, workshops, or utility rooms. Its primary benefit is the integrated active RCD protection, which significantly reduces the risk of electric shock by quickly cutting power during an earth fault. While it offers superior durability thanks to its metal-clad construction, it is important to note that this unit is strictly for indoor use and requires professional electrical installation to ensure full compliance with safety standards.

All features

Model Part NumberRCD07MAVN
BrandTimeguard

Extended Product Information

FAQs

Can I install this in an outdoor shed?

No, this model is designed specifically for indoor use. Outdoor installations require IP-rated enclosures.

What does 'Active' RCD mean?

An active RCD keeps the power supply disconnected in the event of a power failure, preventing the device from switching back on until it is manually reset.

Is this socket compatible with standard UK wall boxes?

Yes, it is designed for use with standard double-gang electrical back boxes.

How often should I test the RCD?

It is recommended to use the test button monthly to ensure the internal tripping mechanism remains functional.

Can I use this for appliances requiring more than 13A?

No, the total load for a double-gang socket should not exceed the standard 13A rating of the circuit.

Troubleshooting

The RCD trips frequently without an obvious fault

Check your connected appliances for dampness or damaged cables, as these often cause nuisance tripping.

Socket fails to provide power after a power cut

This is an active RCD feature; you must manually reset the device after power is restored to ensure safety.

Test button does not trip the power

If the test button fails, the RCD mechanism may be faulty. Disconnect from power immediately and contact a qualified electrician to replace the unit.

Pros and Cons

Pros

  • High level of electrical shock protection
  • Extremely durable metal casing
  • Independent switching for both outlets
  • Prevents accidental re-starts after power loss

Cons

  • Suitable for indoor use only
  • Requires professional installation
  • Bulkier profile compared to standard plastic faceplates

Setup, Compatibility & Care

Installation must be performed by a qualified electrician in accordance with current IET wiring regulations. Before starting, ensure the main power supply is isolated at the consumer unit. The unit fits standard double-gang mounting boxes; ensure the wall surface is level to prevent distortion of the metal casing when tightening the screws. For maintenance, keep the exterior free from dust and debris to ensure the mechanical switches operate smoothly. Periodically test the RCD function using the integrated 'Test' button to ensure the trip mechanism remains responsive.