The new flue system is easy to install with push-fit connections and a telescopic system which, in...The new flue system is easy to install with push-fit connections and a telescopic system which, in most cases, eliminates the need to cut the flue to size. The Vaillant 1.7 metre horizontal flue serves as a pathway for expelling exhaust gases produced by the boiler to the outside environment, ensuring safe and efficient operation of the boiler. It is 1.7 meters long, which allows flexibility in installation to accommodate various building layouts and distances from the boiler to the external wall.
This guide is for homeowners and installers using the Vaillant Horizontal terminal 60/100 PP 1.7m flue system. The system offers easy installation and efficient exhaust gas expulsion, ensuring safe boiler operation. A key consideration is ensuring proper fitting and sealing to prevent leaks. This guide will help you understand the features, setup, and maintenance of your Vaillant flue system.
All features
Model Part Number
0010039327
Brand
Vaillant
Extended Product Information
FAQs
What is the length of the flue?
The flue is 1.7 meters long.
What type of connection does it use?
It uses push-fit connections.
What is the flue designed to do?
The flue is designed to expel exhaust gases from the boiler.
Is this flue compatible with all boilers?
No, it is specifically designed for use with Vaillant boilers.
How do I clean the flue?
Regularly inspect the flue terminal for any blockages or damage. Clean the terminal as needed to maintain optimal performance. Avoid using harsh chemicals when cleaning.
What should I do if the boiler isn't working correctly?
Check the flue for blockages and ensure it's properly connected. If the problem persists, contact a qualified technician.
Troubleshooting
Boiler not starting or running efficiently.
Check the flue terminal for blockages. Ensure the flue is properly connected and sealed. Contact a qualified technician if the problem persists.
Water leaks around the flue.
Check all connections for proper sealing. Tighten connections or replace seals as needed. Contact a qualified technician if the problem persists.
Pros and Cons
Pros
Easy to install due to push-fit connections and telescopic design.
Provides a safe pathway for exhaust gases.
The 1.7-meter length offers flexibility in installation.
Designed for use with Vaillant boilers.
Cons
Requires proper sealing to prevent leaks.
May require professional installation depending on local regulations.
Limited to horizontal installations.
Specific to Vaillant boiler systems.
Setup, Compatibility & Care
Installation: Follow the manufacturer's instructions for proper installation. Ensure all connections are secure and sealed.
Compatibility: This flue system is specifically designed for use with Vaillant boilers. Confirm compatibility with your boiler model before installation.
Positioning: Ensure the flue terminal is positioned correctly outside the building, away from windows, vents, and other potential obstructions.
Care: Regularly inspect the flue terminal for any blockages or damage. Clean the terminal as needed to maintain optimal performance. Avoid using harsh chemicals when cleaning.