This Phoenix Contact M8 sensor/actuator receptacle connector (MPN: 1500363) features a straight, 4...This Phoenix Contact M8 sensor/actuator receptacle connector (MPN: 1500363) features a straight, 4-way M8 to unterminated configuration. It has a current rating of 4 A and an IP rating of IP67, making it suitable for industrial automation and control systems. The cable length is 500mm, with a maximum operating temperature of +85°C and a minimum of -25°C. It utilizes a quick connect mating type and has gold contact plating with a polymer housing material.
Best current price£12.54from Rapid Online - Rapid Electronics Ltd.
This guide is for industrial automation professionals needing reliable sensor and actuator connections. The Phoenix Contact 1500363 M8 cable offers a durable, IP67-rated solution for harsh environments, ensuring robust signal transmission. A key benefit is its pre-assembled, unterminated design allowing for flexible integration. One caveat is the fixed 0.5m cable length, which may require extensions for longer runs.
All features
Model Part Number
1500363
Brand
Phoenix Contact
Extended Product Information
FAQs
What does the IP67 rating mean for this cable?
An IP67 rating means the connector is dust-tight and protected against immersion in water up to 1 meter for 30 minutes. This makes it suitable for demanding industrial environments.
Can I cut this cable to a shorter length?
Yes, you can cut the cable to a shorter length. However, you will need to strip and terminate the wires at the cut end according to your system's requirements.
What is the temperature range for this connector?
The operating temperature range for this connector is from -25°C to +85°C.
What are the advantages of gold contact plating?
Gold contact plating provides excellent conductivity and resistance to corrosion, ensuring a reliable and stable connection over time, even in challenging environments.
Is this cable suitable for high-current applications?
This cable has a current rating of 4 A, which is suitable for most standard sensor and actuator signals. It is not intended for high-power applications.
How do I determine the pinout for the unterminated end?
Standard M8 4-pin assignments are common. Typically, pins 1 and 2 are for signal, pin 3 for voltage, and pin 4 for ground. Always consult your sensor/actuator datasheet and control system documentation for definitive pin assignments.
What is the housing material?
The housing material is a durable polymer, designed for robustness in industrial settings.
Troubleshooting
No signal transmission
Verify all wire connections at the unterminated end are secure and correctly mapped. Check the M8 connector for debris and ensure it's properly seated in the receptacle. Test continuity of each wire with a multimeter.
Intermittent signal loss
Inspect the cable for kinks or damage. Ensure the M8 connector is fully engaged and locked. Check for environmental factors (vibration, moisture) that might be affecting the connection.
Connector does not mate securely
Ensure you are using a standard M8 receptacle. Check both the connector and receptacle for bent pins or damaged threads. Clean both mating surfaces.
Cable jacket is damaged
If the damage is minor and does not expose the conductors, it may still function but should be monitored. For significant damage, the cable should be replaced to maintain its environmental protection rating.
Pros and Cons
Pros
High degree of protection (IP67) for use in harsh conditions.
Reliable signal transmission due to gold-plated contacts.
Flexible integration with its unterminated end.
Compact M8 connector size, ideal for space-constrained applications.
Durable polymer housing for longevity.
Cons
Fixed cable length of 0.5m may be too short for some applications.
Unterminated end requires manual wiring, adding installation time.
Maximum operating temperature of +85°C may limit use in extremely high-temperature environments.
Specific to M8 size, not compatible with larger M12 connectors.
Setup, Compatibility & Care
Setup:
Identify Termination Needs: Determine the wiring requirements for your specific sensor, actuator, or control system.
Prepare Cable End: Carefully strip the outer jacket and insulation from the 0.5m cable end to expose the individual wires.
Connect Wires: Connect the individual wires (typically color-coded) to the corresponding terminals or screw connections on your device, following standard M8 4-pin assignments or your system's specific requirements.
Secure Connection: Ensure all connections are tight and properly insulated.
Compatibility:
Connector Type: Compatible with standard M8 receptacles and devices.
Wiring: Suitable for 4-position signals. Ensure your connected device uses a compatible pinout.
Environmental: Rated for industrial environments with potential dust and water exposure.
Care:
Cleaning: Wipe the connector and cable with a dry or slightly damp cloth. Avoid harsh chemicals or solvents that could damage the polymer housing or cable jacket.
Inspection: Regularly inspect the cable and connector for any signs of physical damage, wear, or corrosion. Ensure the IP67 seal remains intact.
Temperature Limits: Operate within the specified temperature range of -25°C to +85°C.