Robus Universal Occupancy Sensor - RU360-01

The Robus universal passive infrared occupancy sensor 360 degree is designed for both surface and ...

Best current price£9.99from eBay

All Offers

4 offers from £9.99 - £57.16

View price history by clicking the chart icon.

eBayRobus PIR Sensor Ceiling 360 Surface Mount or Recessed White RU360
Free delivery in 1–3 days
£9.99
Visit shop
HSS HireRobus Green Occupancy Director 360Dg Surface Or Recessed Mounting
Free delivery in 1–3 days
£34.80
Visit shop
City Plumbing GBRobus Light Universal 360 Degree Recessed/Surface Passive Infrared Occupancy Sensor Ip20 Ru360-01
Free delivery in 1–3 days
£43.97
Visit shop
B&QB&Q - Universal 360 Degree Recessed/surface Passive Infrared Occupancy Sensor Ip20 Ru360-01
Free delivery in 1–3 days
£57.16
Visit shop

Product Information

Full details

This guide is for users of the Robus Universal Occupancy Sensor (RU360-01). It's designed to help you understand the sensor's features and how to use it effectively, saving energy and improving convenience. This sensor offers adjustable settings for optimal performance but requires careful setup for specific environments. This guide covers setup, usage, troubleshooting, and frequently asked questions to ensure you get the most out of your occupancy sensor.

All features

Model Part NumberRU360-01
BrandRobus

Extended Product Information

FAQs

How do I adjust the time delay?

Locate the time delay adjustment on the sensor and rotate it to set the desired time. Refer to the product manual for specific instructions.

How do I adjust the sensitivity?

Use the sensitivity adjustment to modify the detection range. Reduce sensitivity for smaller areas and increase for larger spaces.

What is the detection angle?

The sensor has a 360-degree detection angle.

Can I use this sensor outdoors?

This sensor is primarily designed for indoor use. Check the product specifications for any outdoor-rated models.

What type of light fixtures can I use with this sensor?

The sensor is compatible with most light fixtures. Ensure the load rating of the sensor meets your fixture's requirements.

How do I clean the sensor?

Use a soft, dry cloth to clean the sensor. Avoid using water or cleaning solvents.

What does the 'natural light inhibit' feature do?

This feature prevents the lights from turning on if there is sufficient ambient light, conserving energy.

Troubleshooting

Lights do not turn on.

Check the power supply and wiring connections. Ensure the time delay and sensitivity are appropriately set.

Lights stay on constantly.

Check for any obstructions in the detection area. Adjust the time delay settings.

Lights turn on and off too frequently.

Adjust the sensitivity settings to reduce the detection range or check for sources of interference.

Sensor not detecting movement.

Check the sensor's field of view for obstructions. Ensure the sensitivity settings are adequate.

Pros and Cons

Pros

  • Energy efficient due to automatic shut-off.
  • Easy installation with plug-in terminal block.
  • Adjustable settings for customized performance.
  • Versatile mounting options (flush or surface).
  • Wide coverage area (360 degrees).

Cons

  • Requires careful adjustment of settings for optimal performance.
  • May require professional installation depending on the setup.
  • Potential for false triggers if not set up correctly.
  • Sensitivity adjustments can be tricky to fine-tune.
  • Coverage area might be too wide for small spaces.

Setup, Compatibility & Care

  1. Installation:
  • Ensure power is switched off before commencing installation.
  • Follow the provided wiring diagram for correct connections.
  • Choose either surface or recessed mounting based on your needs.
  1. Adjustments:
  • Adjust the time delay setting to determine how long the lights stay on after motion ceases.
  • Modify the sensitivity settings to match the size of the area being monitored.
  • Ensure natural light inhibition is correctly set if applicable.
  1. Compatibility:
  • Compatible with most lighting fixtures, check the load rating to ensure it meets your requirements.
  • Confirm the voltage compatibility with your electrical system.
  1. Care:
  • Clean the sensor regularly with a soft, dry cloth.
  • Avoid using harsh chemicals or solvents.