Schneider Electric Circuit Breaker - C60N - M9F11310

The Schneider Electric C60N series MCB has a 10 Amp rated operating current and is used for distri...

Best current price£16.19from Tameson UK

All Offers

8 offers from £16.19 - £71.75

View price history by clicking the chart icon.

Tameson UKSchneider Electric Schneider Multi9 C60n 2A Single Pole Circuit Breaker - M9f11102
Free delivery in 1–3 days
£16.19
Visit shop

Product Information

Full details

The Schneider Electric C60N MCB (M9F11310) is designed for electrical distribution applications, offering reliable protection for circuits. It's ideal for electricians and system integrators needing a robust circuit breaker. A key benefit is its thermal magnetic trip unit and C curve, suitable for inductive loads. One potential consideration is its IP20/IP40 rating, which means it should be installed in an enclosure for environments with dust or moisture.

All features

SeriesC60N
Model Part NumberM9F11310
BrandSchneider Electric

Extended Product Information

FAQs

What is the main purpose of a Type C trip curve?

A Type C trip curve is designed to handle higher inrush currents, typically from inductive loads like motors and transformers. It will not trip immediately on these temporary surges but will still trip for short circuits.

Can this MCB be used for DC circuits?

This specific model (M9F11310) is rated for 240V AC. While some MCBs can be used for DC, it is crucial to check the specific DC voltage rating and application guidelines. This model is primarily intended for AC distribution.

What does '10 kA Breaking Capacity' mean?

It means the circuit breaker is capable of safely interrupting and extinguishing a fault current of up to 10,000 amperes without being destroyed. This is a critical safety rating.

What is the difference between IP20 and IP40?

IP20 indicates protection against solid objects greater than 12.5mm (like a finger) and no protection against water. IP40 indicates protection against solid objects greater than 1mm (like wires) and protection against solid objects up to 1mm in size. For proper protection against dust and water, the MCB should typically be installed within an enclosure that meets or exceeds IP40.

How do I determine if a 10A rating is sufficient for my circuit?

You need to calculate or measure the continuous current draw of the equipment on the circuit. Always select an MCB with a rating equal to or greater than the continuous load, but typically not more than 125% of the continuous load for continuous duty applications. Consult an electrician for precise calculations.

What does 'Green Premium' signify?

Green Premium is Schneider Electric's eco-label indicating that the product complies with the highest environmental standards, is free from hazardous substances (like mercury or lead), and is designed for minimal environmental impact throughout its lifecycle.

Troubleshooting

MCB trips frequently under normal load.

Check the connected load to ensure it does not exceed the 10A rating. Verify if the 'C' curve is appropriate for the load type; an inductive load with high inrush might require a 'C' curve, but if the tripping is sustained, the load might be faulty or the MCB underrated. Inspect wiring for loose connections or short circuits.

MCB will not latch in the 'ON' position.

Ensure the circuit is de-energized before attempting to reset. Check for internal damage to the MCB. If the MCB has tripped due to a fault, the fault must be cleared before it can be reset. If the MCB appears physically damaged or faulty, it should be replaced.

MCB overheats.

Check terminal connections for tightness. Loose connections are a common cause of overheating. Ensure the ambient temperature is within the operating range (-30 to 70 °C). Verify that the load current does not exceed the MCB's rating.

Pros and Cons

Pros

  • Robust construction for reliable performance.
  • Suitable for inductive loads due to the Type C trip curve.
  • High breaking capacity ensures safety during fault conditions.
  • Easy DIN rail mounting for quick installation.
  • Wide operating temperature range for diverse environments.
  • Environmentally certified (Green Premium).

Cons

  • IP rating requires enclosure for dusty or wet environments.
  • Primarily for distribution, not main power supply protection.
  • Specific C curve may not be suitable for all load types (e.g., purely resistive loads might benefit from a B curve).
  • Not designed for DC applications without specific ratings.

Setup, Compatibility & Care

Setup:

  1. Ensure the power to the circuit is completely de-energized.
  2. Mount the MCB onto a standard 35mm DIN rail within an appropriate electrical enclosure.
  3. Connect the incoming power conductors to the designated terminals (typically top).
  4. Connect the outgoing circuit conductors to the corresponding load terminals (typically bottom).
  5. Ensure all connections are secure and properly torqued according to electrical standards.
  6. Close the enclosure door and ensure the MCB toggle is accessible.

Compatibility:

  • Voltage: Rated for 240V AC, suitable for standard single-phase and some three-phase systems.
  • Current: Designed for circuits up to 10A.
  • Mounting: Compatible with standard 35mm top hat DIN rails.
  • Enclosure: Requires an enclosure providing at least IP40 protection for general use.

Care:

  • Cleaning: Periodically inspect the MCB and its connections. Clean the exterior with a dry or slightly damp cloth. Avoid solvents or abrasive cleaners.
  • Environment: Ensure the MCB is installed within its specified operating temperature range (-30 to 70 °C) and that the enclosure maintains adequate ventilation.
  • Testing: It is recommended to perform periodic testing of circuit breakers as per local electrical codes and standards to ensure proper functionality.