This ES12 series impulse relay from Eltako features two potential-free make contacts (NO) and is s...This ES12 series impulse relay from Eltako features two potential-free make contacts (NO) and is suitable for incandescent lamps up to 2000W. By using bi-stable relays, there are no coil losses when energized and therefore no heat generation. In addition, this impulse relay has a standby loss of 0.03-0.4W, a current rating of 16A and very low switching noise. State-of-the-art hybrid technology provides wear-free electronic control with high switching power from a dedicated relay. EAN: 4010312107690 - manufacturer-number: ES12Z-200-UC - Latching relay 8...230V AC/DC Function Electronic switch, Mounting method DIN rail, Width in number of modular spacings 1, Built-in depth 58mm, Number of contacts as normally open contact 2, Number of contacts as normally closed contact 0, Number of contacts as change-over contact 0, Control voltage 1 230 ... 8V, Type of control voltage 1 AC/DC, Frequency control voltage 1 50 ... 50Hz, Control voltage 2 8 ... 230V, Frequency control voltage 2 50 ... 50Hz, Rated switch current 16A, Supply voltage 250 ... 250V, Voltage type of supply voltage AC, Max. incandescent lamp load 2000W, Max. load fluorescent lamp 1000VA, Max. load fluorescent lamp (Duo circuit) 1000VA, Max. load fluorescent lamp (parallel compensated) 500VA, Max. switching current (cos phi = 0.6) 4A, Manual operation possible - ES12Z-200-UC
Best current price£52.15from Rapid Online - Rapid Electronics Ltd.
The Eltako ES12Z-200-UC impulse relay is designed for electrical control applications, offering efficient switching for lighting and other loads. It is ideal for homeowners, electricians, and building managers seeking reliable and energy-efficient control. A key benefit is its low standby loss and ability to handle high incandescent lamp loads, though it requires a DIN rail for mounting. This device features two potential-free make contacts, bi-stable relay technology for zero coil loss, and compatibility with a wide control voltage range.
All features
Series
ES12
Model Part Number
ES12Z-200-UC
Brand
Eltako
Extended Product Information
FAQs
What is the main advantage of using a bi-stable relay like the ES12Z-200-UC?
The primary advantage is zero coil power consumption when the relay is energized, meaning it doesn't generate heat and saves energy. It maintains its state until a new impulse is received.
Can I use this relay for LED lighting?
While not specifically rated for LED, if the total wattage of the LED lights does not exceed the relay's capacity (e.g., 16A general load) and the power factor is suitable, it may work. However, for precise LED control, specialized relays might be more appropriate.
What does 'potential-free contacts' mean?
It means the contacts are isolated from the relay's internal control circuitry and power supply. They can be connected to any voltage or ground as needed for the load.
How do the central ON and central OFF functions work?
These inputs, electrically isolated from the local control, allow a master switch or system to override local commands and turn all connected devices ON or OFF simultaneously.
What is the maximum current rating for non-incandescent loads?
The general rated switch current is 16A. For loads with a power factor of 0.6 (like some motors or transformers), the maximum switching current is 4A.
Does the ES12Z-200-UC require a separate power supply?
No, the supply voltage is the same as the control voltage (8-230V AC/DC), simplifying installation.
What is the width of this relay on a DIN rail?
It occupies one modular spacing unit, which is 18mm wide.
Troubleshooting
Relay does not switch when activated
Verify that the control voltage is within the 8-230V AC/DC range and correctly connected to the input terminals. Ensure the load wiring is secure and the load itself is functional.
Relay is constantly energized or stuck
Check for any voltage present on the control input terminals when the external switch is in the off position. Inspect for damage to the internal relay contacts or control circuitry. Ensure correct wiring for central ON/OFF functions if used.
Overheating or unusual noise
Disconnect power immediately. Check if the connected load exceeds the specified limits (e.g., 2000W incandescent, 16A total current). Ensure adequate ventilation around the device. If the issue persists, the unit may be faulty and require replacement.
Intermittent switching or poor contact
Ensure all connections are tight and free of corrosion. Verify that the control signal is clean and stable. If used for frequent switching, confirm the load is within the rated switching current, especially for inductive loads (4A max at cos phi = 0.6).
Pros and Cons
Pros
Energy efficient with very low standby loss
High load capacity for incandescent lamps
Durable due to wear-free electronic control and bi-stable relay
Versatile control voltage compatibility (8-230V AC/DC)
Quiet operation with low switching noise
Compact DIN rail mountable design
Cons
Requires DIN rail mounting, not standalone
Primarily designed for make contacts; no break contacts included
Specific load limitations for fluorescent lamps compared to incandescent
Setup, Compatibility & Care
Setup:
Ensure the power supply is disconnected before installation.
Mount the ES12Z-200-UC onto a standard DIN rail (TH35) in an electrical enclosure.
Connect the control voltage to the designated terminals (8-230V AC/DC).
Connect the load to the two potential-free make contacts (NO).
Wire any external switches or central control inputs to their respective terminals.
Compatibility:
Control Voltage: 8-230V AC/DC. The supply voltage for the relay can be the same as the control voltage.
Mounting: Compatible with standard 35mm DIN rails (EN 60715 TH35).
Loads: Suitable for incandescent lamps up to 2000W, fluorescent lamps up to 1000VA, and other loads with a maximum switching current of 16A (4A at cos phi = 0.6).
Care:
Keep the device clean and free from dust and moisture.