Warmer 10 Port Underfloor Heating Manifold - 15mm Pipe Connections

This comprehensive 10-port underfloor heating manifold from Wärmer System provides efficient water...

Best current price£196.53from B&Q

One Offer

1 offer from £196.53

View price history by clicking the chart icon.

B&QB&Q - 10 Ports Water Underfloor Heating Manifold With 15mm Pipe Connections 1 Inch Ball Valves Automatic Air Vent Psw Tradesuppliers Ltd
Free delivery in 1–3 days
£196.53
Visit shop

Product Information

Full details

This Wärmer System 10-port manifold is ideal for homeowners and installers managing multi-zone underfloor heating systems, offering precise individual zone temperature control. Its key benefit is efficient water distribution and easy system monitoring. A potential caveat is the need for standard plumbing tools for installation, which may require some DIY experience or professional assistance.

All features

BrandWärmer System

Extended Product Information

FAQs

What size pipes does this manifold support?

This manifold is designed for 15mm pipe connections for the underfloor heating loops.

Can I control each zone independently?

Yes, each port on the manifold corresponds to a different zone, and you can control the water flow to each zone individually.

Does this manifold come with actuators for smart home control?

This product guide focuses on the manifold itself. Actuators for smart home integration are typically sold separately and would connect to the manifold's zone outlets.

How do I purge air from the system using this manifold?

The manifold includes an automatic air vent end unit. During filling, you can also manually open the filling/drain off valve to help expel air. Ensure the system is fully bled before operation.

What is the maximum number of zones this manifold can control?

This is a 10-port manifold, meaning it can control up to 10 individual heating zones.

What is the purpose of the pressure gauge?

The pressure gauge allows you to monitor the system pressure, which is crucial for efficient operation and detecting potential leaks.

Do I need special tools to install this?

The manifold is designed for easy installation with standard plumbing tools. You will typically need pipe cutters, wrenches, and potentially a pipe bender.

Troubleshooting

Manifold is not heating one or more zones

Check if the isolating ball valve for that zone is open. Ensure there are no airlocks by using the automatic air vent. Verify the pipe connections are secure and that the zone is receiving flow from the heating system.

System pressure is dropping

Inspect all connections on the manifold and pipework for leaks. Check the pressure gauge end unit and the filling/drain off valve for any signs of weeping.

Water is escaping from the air vent

This is normal during initial filling or if air is being purged. If it continues after the system has settled, there may be an issue with the seal on the vent or excessive air in the system.

Difficulty connecting pipes

Ensure you are using the correct 15mm fittings and that the pipe ends are clean and properly prepared. Do not overtighten compression fittings.

Pros and Cons

Pros

  • Provides granular control over multiple underfloor heating zones.
  • Includes essential monitoring and maintenance features like a pressure gauge and air vent.
  • Designed for straightforward installation with standard plumbing tools.
  • Durable construction ensures longevity.
  • Efficient water distribution contributes to energy savings.

Cons

  • Requires basic plumbing knowledge or professional installation.
  • 15mm pipe connections might not be compatible with all existing systems without adapters.
  • As a component, it requires a compatible boiler and underfloor heating pipe system to function.

Setup, Compatibility & Care

Setup:

  1. Ensure the main heating system is turned off and depressurized.
  2. Mount the manifold securely to a suitable surface near the underfloor heating pipe entry points.
  3. Connect the main flow and return pipes from your heating system to the corresponding inlets/outlets on the manifold.
  4. Connect the 15mm underfloor heating pipes from each zone to the designated ports on the manifold. Use appropriate fittings for a secure, leak-free connection.
  5. Attach the automatic air vent and pressure gauge end units to their respective ends of the manifold.
  6. Connect the filling/drain off valve.
  7. Slowly fill the system with water, opening the filling valve and the automatic air vent to purge air.
  8. Once filled and purged, check the pressure gauge and ensure all connections are watertight.

Compatibility:

  • The manifold is designed for use with standard underfloor heating systems.
  • Requires 15mm pipe connections for the underfloor heating loops.
  • Compatible with most standard boiler systems and heating system controls. Ensure your boiler has sufficient capacity for the connected zones.

Care:

  • Regularly check the pressure gauge to ensure it is within the recommended operating range for your heating system.
  • Periodically open the automatic air vent slightly to release any accumulated air.
  • Inspect all connections for leaks during routine system checks.
  • When performing maintenance, use the isolating ball valves and the filling/drain off valve to manage water flow safely.