VAILLANT TURBOMAX PRO 28 E VUW 282/2-3 R1 R2 R3 DHW HEAT EXCHANGER 189mm - HTS - 065099

This part fits the following boilers: VAILLANT ecoMAX 824/2 E (2001-2007), VAILLANT ecoMAX 828/2 E...

Best current price£39.18from OnBuy.com

One Offer

1 offer from £39.18

View price history by clicking the chart icon.

OnBuy.comVaillant Turbomax Pro 28 E Vuw 282/2-3 R1 R2 R3 Dhw Heat Exchanger 189Mm 065099 5056511800238
Free delivery in 1–3 days
£39.18
Visit shop

Product Information

Full details

This HTS DHW Heat Exchanger (MPN: 065099) is designed for owners of specific Vaillant ecoMAX and TURBOMAX boilers seeking to restore or enhance hot water performance. Its key benefit is high-efficiency heat transfer, ensuring fast and consistent hot water while improving system efficiency. A potential caveat is that professional installation is recommended for optimal performance and safety. This component is crucial for maintaining your boiler's ability to provide reliable hot water.

All features

Model Part Number065099
BrandHTS

Extended Product Information

FAQs

Which Vaillant boiler models is this heat exchanger compatible with?

This heat exchanger is designed for VAILLANT ecoMAX 824/2 E (2001-2007), VAILLANT ecoMAX 828/2 E (2001-2007), VAILLANT TURBOMAX PRO 28 E VUW 282/2-3 R1, R2, R3, and VAILLANT TURBOMAX PLUS 824 models.

Is professional installation required?

Yes, due to the complexity and safety implications of working with boilers, professional installation by a Gas Safe registered engineer or qualified technician is strongly recommended.

What is the warranty period for this heat exchanger?

This product comes with a 12-month warranty from the manufacturer.

How does this heat exchanger improve system efficiency?

The 189mm design maximizes heat transfer from the boiler's combustion to the water, allowing for faster heating and potentially reducing the amount of energy required to reach the desired temperature, thus improving overall efficiency.

What are the benefits of its durable construction?

The use of high-quality, corrosion-resistant materials ensures the heat exchanger can withstand high temperatures and continuous operation, leading to a longer lifespan and reliable performance.

Can I install this myself if I am experienced with DIY?

While some experienced DIY users may attempt installation, it is crucial to follow all safety procedures and ensure compliance with local regulations. Working with gas and water systems carries inherent risks, and professional installation is always advised for safety and to ensure optimal performance and warranty validity.

Troubleshooting

No hot water or insufficient hot water after installation

Ensure the boiler has been correctly refilled and bled, check all pipe connections to the heat exchanger are secure, and verify that the boiler's settings are appropriate. A professional diagnostic may be needed to check for blockages or airlocks.

Boiler pressure is low or dropping

Check for leaks around the new heat exchanger connections or any other part of the system. Ensure the filling loop is closed. If leaks persist, contact a qualified technician.

Unusual noises (e.g., kettling) from the boiler

This can indicate scale buildup or poor water circulation. Ensure the system has been properly flushed and inhibitors added if necessary. Regular servicing by a professional is recommended.

Pros and Cons

Pros

  • Ensures fast and consistent hot water supply.
  • Contributes to improved boiler energy efficiency.
  • Built with durable, corrosion-resistant materials for longevity.
  • Designed for a precise fit with compatible Vaillant boiler models.
  • Backed by a 12-month warranty for peace of mind.

Cons

  • Requires professional installation for safety and optimal function.
  • Specific compatibility limits its use to certain Vaillant boiler models.
  • Potential for disruption to hot water service during replacement if not pre-planned.

Setup, Compatibility & Care Instructions

Compatibility:

This heat exchanger is specifically designed for the following Vaillant boiler models:

  • VAILLANT ecoMAX 824/2 E (2001-2007)
  • VAILLANT ecoMAX 828/2 E (2001-2007)
  • VAILLANT TURBOMAX PRO 28 E VUW 282/2-3 R1, R2, R3
  • VAILLANT TURBOMAX PLUS 824

Setup:

Installation of this heat exchanger requires a thorough understanding of boiler systems and should ideally be performed by a Gas Safe registered engineer or a qualified heating technician. The process involves:

  1. Isolating the boiler from the mains gas and electricity supply.
  2. Draining down the boiler's primary circuit.
  3. Carefully removing the old heat exchanger.
  4. Installing the new HTS heat exchanger, ensuring all seals and connections are secure.
  5. Refilling and bleeding the heating system.
  6. Restoring power and gas supply, and conducting a full system check.

Care:

This heat exchanger is constructed from durable, corrosion-resistant materials and requires no routine user maintenance. Its performance is primarily dependent on the overall health of the boiler system, including water quality and regular servicing. Ensure your boiler undergoes annual servicing by a qualified professional to maintain optimal operation and prevent potential issues that could affect the heat exchanger.