MK Electric Sentry RCD - 100A 30MA 230V DP Type A 2 Module

Currently unavailable

Currently unavailable
This MK Electric Sentry RCD is designed for electricians and homeowners needing reliable protection against earth faults. Its key benefit is providing robust safety with a 100A current rating and 30mA sensitivity. A potential caveat is that Type A protection is specific and may not cover all fault types encountered in very complex industrial settings.
| Series | Sentry |
|---|---|
| Model Part Number | Sentry RCD 100A 30MA 230V DP Type A 2 Module |
| Brand | MK Electric |
Type AC RCDs detect sinusoidal AC earth leakage currents. Type A RCDs offer enhanced protection by detecting both sinusoidal AC and pulsating DC earth leakage currents, making them more versatile for modern installations with electronic equipment.
No, this RCD is a Residual Current Device (RCD) which protects against earth leakage faults. It does not protect against overcurrents or short circuits. These protections are typically provided by a Miniature Circuit Breaker (MCB) used in conjunction with the RCD.
No, this is a 230V, 2-pole (single-phase) RCD and is not suitable for 3-phase applications.
It is recommended to test the RCD using its test button at least every six months to ensure its continued safe operation.
DP stands for Double Pole, meaning the RCD switches both the live and neutral conductors simultaneously.
It refers to the width of the RCD, typically meaning it occupies two standard 18mm spaces on a DIN rail.
Check for faulty appliances connected to the protected circuit. Perform a test with all appliances switched off. If it still trips, the RCD itself may need checking by a qualified electrician.
Ensure the incoming supply is live. If the supply is correct, the RCD may be faulty and requires replacement by a qualified electrician.
This can sometimes indicate a slight imbalance in the load current or internal component resonance. While often harmless, if accompanied by heat or tripping, it warrants inspection by a qualified electrician.
Setup:
This RCD is designed for mounting on a standard DIN rail within an electrical enclosure. Ensure the power supply to the enclosure is isolated before commencing installation. The device is double pole, meaning both the live and neutral conductors from the incoming supply must be connected to the respective terminals, and the outgoing circuit conductors connected to the load terminals. The neutral terminal is located on the left.
Compatibility:
Care: