Rittal Power Distribution Unit - Grey - 7240330


Best current price£299.83from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Rittal Grey 9-Outlet Pdu With Surge Protection And Emi Filter (European Socket) - 7240330
Visit shop

Best current price£299.83from Tameson UK
Shopping.co.uk recommended and popular offers
Rittal Grey 9-Outlet Pdu With Surge Protection And Emi Filter (European Socket) - 7240330
Visit shop1 offer from £299.83
View price history by clicking the chart icon.
This Rittal DK 7240.330 Power Distribution Unit (PDU) is designed for IT professionals and data center administrators needing reliable, rack-mounted power. Its key benefit is providing 9 surge-protected Type D outlets with a 16A capacity in a space-saving aluminum chassis. A potential caveat is the specific Type D outlet compatibility, which may require adapters for non-standard equipment.
| Colour | Grey |
|---|---|
| Model Part Number | 7240330 |
| Brand | Rittal |
The Rittal DK 7240.330 features 9 Type D AC outlets.
The PDU has a maximum current capacity of 16 Amperes (A).
Yes, it is specifically engineered for 482.6 mm (19") rack installations, offering versatile mounting options.
Yes, it includes integrated overvoltage protection to safeguard connected equipment.
The power cord is 2 meters long.
No, this PDU uses Type D outlets. You will need to use appropriate plug adapters for other plug types such as UK (Type G) or EU (Type C/F).
Warranty information should be confirmed with the retailer or Rittal directly, as it can vary by region and vendor.
EMI (Electromagnetic Interference) filtering helps to reduce electrical noise and interference, providing cleaner power to sensitive electronic devices.
Verify the PDU is securely plugged into a live power outlet. Check if the circuit breaker on the PDU (if applicable) has tripped. Ensure the connected devices are functioning and their plugs are fully inserted into the PDU outlets.
Check the main power cord connection for tightness. Inspect the power cord for any visible damage. Ensure the total power draw of connected devices does not exceed the PDU's 16A maximum capacity. Consider if EMI or surge issues are present and if the filters/protection are functioning.
Ensure the EMI filter is functioning. Try connecting the device directly to the power source to rule out issues with the device itself. If the problem persists, the PDU's filtering may be insufficient for highly sensitive equipment.
This PDU uses Type D outlets. If your equipment uses a different plug type (e.g., Type C, G, F, or others), you will need to use compatible plug adapters. Ensure adapters are rated for the appropriate current and voltage.
Setup:
Compatibility:
Care: