Scan Twin Full Face Respirator - Silicone

The Scan Twin Full Face Respirator offers comprehensive protection and comfort in various environm...

Best current price£59.54from B&Q

All Offers

3 offers from £59.54 - £81.64

View price history by clicking the chart icon.

B&QB&Q - Fsm9800 Twin Full Face Respirator No Filters Scapperespff
Free delivery in 1–3 days
£59.54
Visit shop
Power Tools DirectScan Fsm9800 Twin Full Face Respirator No Filters
£5.95 delivery
£69.91
Visit shop
Blueperry agriculture (UK)Scan Twin Full Face Respirator Fsm9800
Free delivery in 1–3 days
£81.64
Visit shop

Product Information

Full details

The Scan Twin Full Face Respirator is designed for professionals needing robust respiratory and eye protection in hazardous environments. Its primary benefit is providing a sealed defense against dust, fumes, vapors, gases, and projected debris, ensuring both breathing safety and clear vision. A key consideration is that it is supplied without filters, requiring separate purchase. This reusable respirator features a comfortable silicone construction, a high-impact polycarbonate visor, and an adjustable headband for a secure fit, making it suitable for extended wear.

All features

BrandScan

Extended Product Information

FAQs

Do I need to buy filters separately?

Yes, the Scan Twin Full Face Respirator is supplied without filters. You will need to purchase compatible Scan particle and/or gas cartridges separately based on the hazards you will be exposed to.

How do I ensure a proper seal?

A proper seal is achieved by adjusting the 4-point headband until the respirator fits snugly against your face without gaps. Always perform a user seal check as instructed by the manufacturer before each use.

What type of contaminants does this respirator protect against?

When fitted with appropriate filters, it protects against dust, fumes, vapors, and gases. The full face design also protects the eyes from projected debris and splashes.

Can I wear glasses or goggles with this respirator?

No, this is a full-face respirator with an integrated visor that provides eye protection. You cannot wear separate glasses or goggles with it.

How often should I replace the filters?

Filter replacement depends on the type of filter, the concentration of contaminants, and your breathing rate. Follow the manufacturer's guidelines for your specific filters and replace them when breathing becomes difficult, the filter is damaged, or according to a predetermined schedule.

Is this respirator suitable for extended wear?

Yes, it is constructed from soft silicone and features an exhalation valve to reduce heat and moisture, making it designed for comfort during extended wear.

What standard does this respirator meet?

This respirator is certified to EN136:1998 standards for full face masks.

Troubleshooting

Respirator leaks around the face seal.

Ensure the 4-point headband is adjusted correctly and provides a snug fit. Clean the sealing surfaces of the facepiece and your skin. Perform a seal check following the manufacturer's instructions.

Difficulty breathing or poor airflow.

Check if the attached filters are clogged or expired. Replace filters if necessary. Ensure the exhalation valve is clean and functioning properly.

Visor fogs up excessively.

Ensure the exhalation valve is not blocked. Use anti-fog wipes or solutions specifically designed for respirators if the issue persists, though proper ventilation via the exhalation valve should minimize this.

Filters are difficult to attach.

Ensure you are using compatible Scan bayonet-fit filters. Align the connectors correctly before attempting to push and twist them into place. Check for any debris in the bayonet slots.

Pros and Cons

Pros

  • Provides dual respiratory and eye protection.
  • Comfortable for extended wear due to silicone construction.
  • Adjustable fit ensures a reliable seal.
  • Clear vision is maintained with the polycarbonate visor.
  • Compatible with various Scan filter cartridges for adaptability.
  • Certified to EN136:1998 standards.

Cons

  • Filters are not included and must be purchased separately.
  • Requires proper fit testing to ensure effectiveness.
  • Can be warmer than half-face respirators during high exertion.
  • Requires regular maintenance and cleaning.

Setup, Compatibility & Care

Setup:

  1. Filter Selection: Choose appropriate Scan particle or gas cartridges based on the specific hazards present in your work environment. Ensure they are certified for the contaminants you expect.
  2. Filter Attachment: Align the bayonet connectors on the respirator with the corresponding slots on the filter cartridges. Push the cartridges in and twist clockwise until they lock into place.
  3. Headband Adjustment: Loosen the straps on the 4-point headband. Place the respirator on your face, ensuring it sits comfortably. Adjust each strap evenly until a tight, secure seal is achieved around the face. Perform a seal check (refer to manufacturer instructions).

Compatibility:

  • This respirator is designed to accept the Scan range of bayonet-fit particle and gas cartridges. Ensure you use only compatible filters.

Care and Maintenance:

  • Cleaning: After each use, clean the inside and outside of the respirator. Use a mild soap and warm water solution with a soft cloth. Rinse thoroughly with clean water and allow to air dry completely away from direct heat or sunlight. Do NOT use solvents or abrasive cleaners.
  • Inspection: Before each use, inspect the respirator for damage, including cracks in the face shield, tears in the silicone, or damage to the headband and straps. Check the exhalation valve for proper function and cleanliness.
  • Storage: Store the respirator in a clean, dry place, preferably in its original packaging or a dedicated storage container, away from direct sunlight and chemicals.