Diesel Generator max 7500 W (400 V) / 6400 W (230 V) - KS 9200HDE-1/3 ATSR
The KS 9200HDE-1/3 ATSR diesel generator features a soundproof housing and a VTS phase switching s...The KS 9200HDE-1/3 ATSR diesel generator features a soundproof housing and a VTS phase switching system, offering a maximum power output of 7500 W (400 V) / 6400 W (230 V) with a 1x16 A connection. Engines are manufactured under license from DIMAX Int. GmbH and branded with the Könner & Söhnen logo, ensuring a power reserve for stable voltage output. All engines undergo rigorous testing for long continuous operation and quality control with individual serial numbers. The unique VTS (Voltage Transfer Switch) system allows the generator to function as both a single-phase (230V) and three-phase (400V) unit with minimal power loss, each mode protected by automatic safeguards. The integrated ATS (Automatic Transfer Switch) unit automatically starts the generator and manages the load during main power outages, returning to mains power when it's restored. For winter operation, the "HEAVY DUTY" series diesel generators include a pre-start heating function. The all-season, noise-absorbing, vandal-proof casing protects the generator, extends its lifespan, and includes handles and a 4-wheel transport set for easy mobility. Weight: 370.37660016 pounds.
K&S Emergency Generator 230V 400V Diesel Power 7.5kW AtsFree delivery in 1–3 days£3,041.61Visit shop →
Ford Emergency Power Unit AVR 400V Diesel Generator Power Generator 7.9kW ATSFree delivery in 1–3 days£3,724.10Visit shop →
Product Information
Full details
This guide helps owners and operators of the Könner & Söhnen KS 9200HDE-1/3 ATSR diesel generator understand its features and get the most out of their unit. Ideal for both single-phase (230V) and three-phase (400V) power needs, this generator offers reliable performance with its unique VTS system and integrated ATS. Keep in mind that while the unit is designed for ease of use, understanding its operational parameters and performing regular maintenance is key to maximizing its lifespan.
All features
Model Part Number
KS 9200HDE-1/3 ATSR
Brand
Könner & Söhnen
Extended Product Information
FAQs
What type of fuel does the generator use?
The generator uses diesel fuel. Always consult the user manual for the correct fuel specifications.
What is the oil capacity, and what type of oil should I use?
Refer to the user manual for the exact oil capacity and the recommended oil type. Using the correct oil is crucial for engine performance.
How often should I change the oil?
Follow the oil change intervals specified in the user manual. This is typically after the first 20 operating hours and every 100 hours thereafter, or at least annually.
What should I do if the generator overheats?
Shut down the generator immediately and allow it to cool. Check the oil level, and inspect the cooling system for any obstructions. If the problem persists, contact a qualified technician.
Can I use the generator in wet weather?
The generator is designed with an IP23 rating. While it can withstand some moisture, avoid operating it in heavy rain or flooding. Protect it from direct exposure to water.
What is the warranty period?
Warranty information can be found in the product documentation or by contacting the manufacturer or seller.
Troubleshooting
Generator fails to start.
Check fuel level, battery connection, and ensure the fuel valve is open. Also, consult the user manual for starting procedures.
Generator produces low voltage.
Check the fuel level, and ensure there are no blockages. Inspect the generator's circuit breakers. If the problem persists, contact a qualified technician.
Generator runs but does not produce power.
Check the circuit breakers and outlets. Inspect the wiring for any damage. If the problem persists, contact a qualified technician.
ATS does not activate the generator during a power outage.
Check the ATS connections and settings. Ensure that the generator is properly connected to the ATS unit. Verify the ATS settings.
Pros and Cons
Pros
Versatile power output with the VTS system, supporting both 230V and 400V devices.
Automatic operation with the integrated ATS unit, providing seamless power during outages.
Durable and protected design with a noise-absorbing, vandal-proof casing.
Easy to move with the included transport wheels.
Reliable engine performance with engines manufactured under license from DIMAX Int. GmbH.
Cons
Diesel generators require regular maintenance, including oil changes and filter replacements.
The generator's weight (168 kg) may make manual handling difficult without assistance.
Fuel tank capacity is 11 L, which may require frequent refueling during extended use.
Noise level of 69 dB might be a concern in noise-sensitive environments.
Setup, Compatibility & Care
Placement: Place the generator on a level surface in a well-ventilated area. Keep it away from flammable materials.
Fueling: Use diesel fuel. Follow the manufacturer's recommendations for fuel type and capacity (11 L).
Connecting Devices: Ensure the total power consumption of the connected devices does not exceed the generator's maximum output (7500 W / 6400 W).
Starting: Follow the starting instructions in the user manual, especially if using the pre-start heating function during winter.
Maintenance:
Check oil levels regularly.
Replace the oil and filters according to the maintenance schedule in the user manual.
Clean or replace the air filter as needed.
Inspect the unit for any signs of damage.
Compatibility: Ensure that the connected devices are compatible with the generator's output voltage (230V or 400V) and frequency (50 Hz).