Spectra Synergy Gold Electric Breast Pump

The Synergy Gold electric breast pump offers the most advanced and up-to-date technology in the in...

Best current price£224.95from OnBuy.com

All Offers

2 offers from £224.95 - £244.95

View price history by clicking the chart icon.

OnBuy.comSpectra Synergy Gold Dual Adjustable Electric Breast Pump
Free delivery in 1–3 days
£224.95
Visit shop
eBaySpectra Synergy Gold Dual Adjustable Electric Breast Pump
Free delivery in 1–3 days
£244.95
Visit shop

Product Information

Full details

The Spectra Synergy Gold is designed for breastfeeding mothers seeking advanced technology and personalized comfort. Its key benefit is the ability to adjust each side independently, optimizing efficiency and ease during pumping sessions. A potential caveat is the need for a personal accessory kit for each user to maintain hygiene in multi-user scenarios. This electric breast pump features a true closed system for milk safety and includes a built-in LED lamp for convenient nighttime use.

All features

Model Part Number9894276
BrandSpectra

Extended Product Information

FAQs

How do I clean the Spectra Synergy Gold breast pump components?

Wash detachable parts like breast shields, bottles, valves, and backflow protector components with warm, soapy water. Rinse thoroughly and air dry. The motor unit and adapter should only be wiped with a damp cloth and never immersed in water or microwaved. Refer to the manual for specific sanitization instructions for washable parts.

Can I share my Spectra Synergy Gold pump with another person?

While the motor unit can be shared, each user must use their own new personal accessory kit, including breast shields, bottles, tubing, backflow protectors, and valves, to maintain hygiene and prevent contamination.

What is the benefit of independent side adjustment?

Independent side adjustment allows you to customize the suction strength and cycle speed for each breast separately. This caters to individual comfort, optimizes milk production, and can make pumping sessions more efficient, especially for mothers with different needs on each side.

How do I use the LED lamp feature?

The LED lamp is integrated into the pump. It provides a mild, indirect light that can be activated as needed for breastfeeding or pumping in low-light conditions without disturbing others.

What does 'true closed system' mean?

A true closed system means there is a physical barrier (the backflow protector) between the milk and the pump's motor and tubing. This prevents any milk or contaminants from entering the pump mechanism, ensuring the purity of the expressed milk.

How do I engage the mute mode?

To enable mute mode, press and hold the massage mode function button for approximately 3 seconds. Press and hold the same button again for 3 seconds to turn mute mode off.

What should I do if I experience nipple pain?

If you feel pain or discomfort, immediately switch off the pump and gently remove it from your breast. You can release suction by inserting a clean finger between your breast and the breast shield or by turning off the pump. Check for proper flange fit and suction settings.

Troubleshooting

Pump not turning on

Ensure the power adapter is securely plugged into both the pump and a working electrical outlet. Check the power cord for any damage.

Low or no suction

Verify that all tubing connections are secure. Check for any kinks or blockages in the tubing. Ensure the breast shield and backflow protector are properly assembled and that the valve is correctly attached and undamaged. Inspect all seals.

Milk leaking from tubing

This indicates a breach in the closed system. Immediately stop pumping. Check that the backflow protector is assembled correctly with all its parts (silicone membrane, caps) and that the tubing is firmly attached to the backflow protector. Ensure the bottle is screwed on tightly.

Discomfort during pumping

Adjust the vacuum level to a more comfortable setting. Ensure the breast shield is the correct size and centered on the nipple. Try a different cycle setting. If pain persists, stop pumping and consult the manual or a lactation professional.

LED lamp not working

Check that the pump is powered on. If the issue persists, contact customer support.

Pros and Cons

Pros

  • Independent control for each breast allows for a highly personalized pumping experience.
  • Closed system ensures milk hygiene and safety.
  • Built-in light is a thoughtful addition for nighttime use.
  • All-inclusive kit means users can start pumping immediately.
  • Adjustable vacuum and cycle settings enhance comfort and efficiency.

Cons

  • Requires a separate personal accessory kit for each user to maintain hygiene standards.
  • The motor unit and AC/DC adapter should never be immersed in water or other liquids.
  • Not suitable for use while bathing, sleeping, or feeling drowsy.
  • Small parts pose a choking hazard and must be kept out of reach of children.

Setup, Compatibility & Care Instructions

Setup:

To begin, ensure all components are clean before first use. Connect the tubing to the pump and attach the breast shields, backflow protectors, and bottles. Select your preferred breast shield size (28mm shields are included). Connect the power adapter.

Usage Guidance:

Start with a low vacuum level and gradually increase it to a comfortable and effective setting. To use the mute mode, press and hold the massage mode function for 3 seconds; press and hold again to disable.

Compatibility:

The Spectra Synergy Gold is designed to work with its proprietary accessories. For multiple users, a new, separate personal accessory kit (including breast shields, bottles, tubing, backflow protectors, and valves) must be used for each individual.

Care and Cleaning:

  • Motor Unit and Adapter: These parts should *never* be immersed in water or placed in a microwave. Clean the motor unit with a slightly damp cloth if necessary.
  • Detachable Parts: Breast shields, backflow protectors (silicone membrane, uppercase, lowercase caps), duckbill valves, tubing, and bottles can typically be washed with warm, soapy water. Rinse thoroughly and air dry completely. Refer to the product manual for specific sanitization methods (e.g., boiling, steam sanitizing) suitable for these components.
  • Inspection: Before each use, carefully inspect all components for any signs of damage such as cracks, chips, tears, or discoloration. Discontinue use and replace any damaged parts immediately.

Price History

DatePrice
Visit shop