Manthorpe Double Pantile Tile Vent - Red

The Manthorpe Antique Red Double Pantile Tile Vent provides an effective and discreet solution for...

Best current price£45.41from B&Q

One Offer

1 offer from £45.41

View price history by clicking the chart icon.

B&Q - Manthorpe Antique Red Double Pantile Tile Vent
Free delivery in 1–3 days
£45.41
Visit shop

Product Information

Full details

The Manthorpe Double Pantile Tile Vent in Antique Red is designed for homeowners and tradespeople needing to ventilate concrete double pantile roofs. Its key benefit is providing discreet, consistent airflow to reduce condensation and moisture issues. A potential caveat is its specific suitability only for double pantile roof types. This vent integrates seamlessly, offering a durable and weather-resistant solution that maintains roof aesthetics.

All features

ColourRed
Model Part NumberHS-GTV-DP-AR
BrandManthorpe

Extended Product Information

FAQs

What type of roof tiles is this vent compatible with?

This vent is specifically designed for concrete double pantile roof tiles.

How much ventilation does this tile vent provide?

It offers a free vent area of 10,000mm², contributing to adequate airflow in the roof space.

What is the minimum roof pitch required for installation?

The minimum roof pitch required for this vent is 20°.

Can this vent be installed on any roof orientation?

Yes, as long as the roof pitch meets the minimum requirement of 20° and the tile type is compatible.

How often should I clean the tile vent?

It is recommended to visually inspect the vent periodically, especially after strong winds or storms, and clear any obstructions. Typically, a light clean once a year is sufficient.

Does the antique red color fade over time?

The vent is manufactured from durable, weather-resistant materials designed for long-term use. While colors can naturally weather over many years, significant fading is unlikely under normal conditions.

What is the maximum headlap for installation?

The maximum headlap for this tile vent is 100mm.

Troubleshooting

No noticeable airflow

Ensure the vent is not blocked by debris, leaves, or nesting materials. Check that the tile above is not significantly overlapping the vent, restricting airflow. Verify installation against the minimum pitch and headlap requirements.

Water ingress around the vent

Confirm the vent is installed with the correct headlap (maximum 100mm) and that the surrounding tiles are properly seated. Check for any cracks or damage to the vent itself and replace if necessary. Ensure roof felt or membrane is correctly positioned beneath the vent.

Vent color does not match tiles

While designed to blend, slight color variations in tiles can occur. This is an aesthetic issue and does not affect performance. Consider adjacent tile colors for the best match during installation.

Pros and Cons

Pros

  • Effectively reduces roof space condensation and moisture.
  • Aesthetically pleasing, blending with antique red double pantile roofs.
  • Durable construction ensures long-term performance against weather.
  • Specifically designed for a secure fit on double pantile tiles.
  • Provides a substantial free vent area for adequate airflow.

Cons

  • Only suitable for concrete double pantile roof tiles.
  • Requires correct installation to ensure weatherproofing and airflow.
  • Color may not match all variations of antique red tiles perfectly.

Setup, Compatibility & Care

Compatibility: This vent is specifically designed for use with concrete double pantile tiles. It is not suitable for other tile profiles or roof types.

Setup: Installation involves replacing a single tile with the vent. The vent is designed to sit within the roof tiling course, ensuring it is integrated at the correct headlap.

  1. Identify the location for the vent, considering ventilation requirements and tile pitch (minimum 20°).
  2. Carefully remove one double pantile tile.
  3. Position the Manthorpe vent, ensuring it overlaps correctly with the tile below (maximum headlap 100mm) and is covered by the tile above.
  4. Secure the vent as per standard roofing practices.

Care: The vent requires minimal maintenance. Periodically check for any obstructions like debris or nesting material that might block airflow. Cleaning can be done with a soft brush or a damp cloth if necessary. Avoid using harsh chemicals or abrasive materials that could damage the plastic.

Specifications Summary:

  • Size: 418 x 332mm
  • Free Vent Area: 10,000mm²
  • Minimum Roof Pitch: 20°
  • Maximum Headlap: 100mm