Setup, Compatibility & Care
Installation must be performed by a qualified plumber to ensure the system is correctly balanced. The valves utilize 15mm compression fittings for the pipework and a 1/2 inch BSPT connection for the radiator.
Important: These valves are NOT bi-directional. You must install the thermostatic head on the flow pipe and the lockshield on the return pipe. Failure to follow this orientation will result in incorrect operation or noise in the system.
For care, wipe the brass finish with a soft, damp cloth only. Avoid abrasive cleaners or acidic chemicals, which can strip the protective antique coating or lead to tarnishing over time.