Knauf Vapour Panel Tapered Edge Plasterboard - 2400 x 1200 x 12.5mm
The Knauf Vapour Panel TE Plasterboard integrates advanced moisture protection with conventional p...The Knauf Vapour Panel TE Plasterboard integrates advanced moisture protection with conventional plasterboard functionality. Featuring metallised polyester foil laminated on the reverse, this 12.5mm panel delivers an efficient vapour barrier for areas where warm and cold building elements converge. Engineered for loft conversions, external wall applications, and pitched roof installations, this panel addresses moisture ingress concerns in demanding environments. The tapered edge design facilitates seamless jointing and professional finishing across residential and commercial projects. Compatible with standard tools including Stanley knives and straight edges, the Vapour Panel TE requires no specialist equipment for cutting or installation. Fully compliant with BS1230 Part 1 1985 standards, this solution combines reliable vapour control with straightforward application for professional and DIY applications.
Features & Benefits:
Metallised polyester foil laminated on reverse for enhanced water vapour control.
Ideal for loft conversions, internal faces of external walls, and pitched roof scenarios.
Tapered edge design enabling seamless jointing and professional finish.
Easy to score and snap with standard Stanley knife and straight edge, no specialist tools required.
Fully compliant with BS1230 Part 1 1985 standards for reliability and safety.
Dimensions: 2400 x 1200 x 12.5mm.
Best current price£20.39from Materials Market Trading UK Ltd
Knauf Vapour Panel Tapered Edge Plasterboard 2400 x 1200 x 12.5mm for Moisture Control in Lofts and Pitched Roofs£25.00 delivery£30.22Visit shop →
Product Information
Full details
This guide is for builders, renovators, and DIY enthusiasts working on projects requiring advanced moisture protection. The Knauf Vapour Panel TE Plasterboard provides an integrated vapour barrier, simplifying installation and enhancing building performance in moisture-prone areas like loft conversions and external walls. A key consideration is ensuring proper sealing of all joints and penetrations to maintain the vapour barrier's integrity.
All features
Model Part Number
243708
Brand
Knauf Drywall
Extended Product Information
FAQs
Which side of the Knauf Vapour Panel TE should face outwards?
The metallised polyester foil side should always face the warm side of the building envelope (towards the heated interior) to effectively prevent moisture ingress.
What tools are needed to cut this plasterboard?
You can cut the Knauf Vapour Panel TE using a standard Stanley knife and a straight edge. No specialized power tools are required for cutting.
How do I ensure the vapour barrier is continuous?
All joints between panels and around any openings must be meticulously sealed with a compatible vapour-resistant tape and adhesive. Ensure the tape adheres well to the foil surface.
Can I use this on any wall?
It is ideal for internal faces of external walls, loft conversions, and pitched roofs where moisture control is crucial. Consult building regulations for specific applications.
What are the dimensions of the panel?
The panels measure 2400mm in length, 1200mm in width, and have a thickness of 12.5mm.
Does this panel require special jointing compounds?
While it uses standard plasterboard finishing techniques, ensure the jointing compound and tape used are compatible and provide a continuous vapour seal with the foil backing.
Is this product compliant with UK building standards?
Yes, the Knauf Vapour Panel TE Plasterboard is fully compliant with BS1230 Part 1 1985 standards.
Troubleshooting
Vapour barrier integrity compromised by a tear in the foil
Repair small tears using a compatible vapour-resistant tape, ensuring a secure bond to the foil surface. For larger damage, consider replacing the affected panel section or the entire panel.
Joints not sealing effectively
Ensure surfaces are clean and dry before applying vapour tape. Use a sufficient overlap of tape and press firmly to achieve a good seal. Re-apply tape if necessary, ensuring full adhesion.
Panel surface is uneven after finishing
Check that the framing is level and that screws are driven consistently. Ensure adequate jointing compound has been applied and smoothed correctly. Allow sufficient drying time between coats.
Pros and Cons
Pros
Provides a dual function of plasterboard and vapour barrier, reducing the need for separate materials.
Simplifies installation in areas prone to condensation and moisture ingress.
Achieves a professional, seamless finish due to the tapered edge design.
Easy to cut and handle with standard DIY tools.
Meets recognized industry standards for quality and performance.
Cons
Requires careful attention to joint sealing to maintain vapour barrier effectiveness.
Not intended for use in areas of continuous high humidity or direct water contact without further protective measures.
The metallised foil side must be installed facing the warm side of the construction for optimal performance.
May require specific jointing compounds to ensure full compatibility with the foil backing.
Setup, Compatibility & Care
Setup:
Ensure the panel is installed with the metallised polyester foil facing the warm side of the building envelope (i.e., towards the interior of the heated space).
Fix the panels to timber or metal framing using appropriate drywall screws, ensuring they are driven flush with the surface without tearing the paper facing.
All joints, both between panels and around openings (windows, doors, electrical boxes), must be sealed using a suitable vapour-resistant tape and adhesive designed for this purpose. Ensure the tape adheres firmly to both the foil surface and the plasterboard.
Apply jointing compound over the taped seams and screw heads, following standard plasterboard finishing techniques.
Compatibility:
Compatible with standard timber and metal stud framing systems.
Requires specific vapour-resistant tape and adhesive for joint sealing.
Can be decorated with standard wallpaper or paint systems after appropriate priming and finishing.
Care:
Store panels flat in a dry environment to prevent damage.
Handle with care to avoid puncturing or tearing the foil backing.
Clean surfaces with a dry or slightly damp cloth. Avoid abrasive cleaners.