ABB Miniature circuit breaker - 3-Pole, 10A, Curve B

The ABB S203-B10 is a miniature circuit breaker designed for thermal magnetic tripping. It feature...

Best current price£21.19from OnBuy.com

All Offers

21 offers from £21.19 - £140.50

View price history by clicking the chart icon.

OnBuy.comAbb S203â B16â Circuit Breaker 16Â A 4016779609203
Free delivery in 1–3 days
£21.19
Visit shop
eBayABB S203-B32 Circuit Breaker 3-Pole 32A 230/400V AC
Free delivery in 1–3 days
£43.88
Visit shop
Rapid Online - Rapid Electronics Ltd.ABB 2CDS253001R0325 S203-B32 Circuit Breaker 3-Pole 32A 230/400V AC
Free delivery in 1–3 days
£58.34
Visit shop
Tameson UKAbb System Pro M Compact Circuit Breaker - 2Cds253001r0105
Free delivery in 1–3 days
£89.22
Visit shop

Used Offers

2 offers from £14.99 - £15.47

View price history by clicking the chart icon.

eBayABB 16 AMP CURVE B 6kA TRIPLE POLE MCB CIRCUIT BREAKER 2CDS253001R0165 S203
Free delivery in 1–3 days
£14.99
Visit shop

Product Information

Full details

The ABB S203-B10 is a 3-pole miniature circuit breaker designed for reliable overload and short-circuit protection in AC and DC electrical systems. It's ideal for residential, commercial, and industrial applications requiring a B-curve tripping characteristic for sensitive equipment. While offering robust protection and compatibility with add-on devices, users should note its specific IP20 rating, making it suitable for indoor, dry environments only.

All features

SeriesSystem M Pro S200
Model Part Number352311
BrandABB

Extended Product Information

FAQs

What is the difference between B, C, and D curve breakers?

The curve (B, C, D) refers to the magnetic tripping level. B-curve breakers trip between 3-5 times the rated current, C-curve between 5-10 times, and D-curve between 10-20 times. B-curve is used for sensitive loads like electronics, C-curve for general loads, and D-curve for high inrush current devices like motors.

Can this breaker be used for DC circuits?

Yes, the ABB S203-B10 is suitable for DC voltage applications up to 125V.

What does IP20 mean?

IP20 means the device is protected against solid objects larger than 12.5mm (like a finger) but offers no protection against water ingress. It is intended for use in dry, indoor environments.

How do I determine if a 3-pole breaker is needed?

A 3-pole breaker is typically required for 3-phase power systems or for circuits where all three phases must be disconnected simultaneously for safety, such as certain types of industrial equipment or main incomer protection.

What is the breaking capacity?

The breaking capacity (Icn/Icu) is the maximum fault current the breaker can safely interrupt without being destroyed. The S203-B10 has a breaking capacity of 6kA according to EN 60898 and up to 20kA according to IEC 60947-2, which is suitable for most residential and commercial installations.

Can I add accessories like auxiliary switches to this breaker?

Yes, the S200 series, including the S203-B10, is compatible with additional equipment like auxiliary switches and signal contacts that can be mounted on the side.

What is the operating temperature range?

The breaker can operate in ambient temperatures ranging from -25°C to 55°C.

Troubleshooting

Breaker trips immediately upon power-up

This indicates a short circuit in the connected load or wiring. Disconnect all loads, check wiring for faults, and reconnect incrementally to identify the faulty circuit or device.

Breaker trips intermittently under normal load

Check for loose connections at the breaker terminals or the load. Ensure the connected load does not exceed the breaker's rated current (10A). Overheating of wiring or the connected device can also cause nuisance tripping.

Breaker does not trip when a fault is suspected

Verify the breaker is correctly installed and energized. Test the breaker's tripping function using a suitable testing device. If the breaker fails to trip during testing, it may be faulty and requires replacement.

Breaker feels warm to the touch during operation

Slight warmth can be normal under moderate load. However, if the breaker is excessively hot, it may indicate an overload condition, loose connections, or a potentially failing breaker. Investigate immediately.

Pros and Cons

Pros

  • Reliable thermal-magnetic tripping for overload and short-circuit protection.
  • B-curve characteristic is suitable for sensitive electronic loads.
  • Compatible with additional equipment for expanded functionality.
  • Robust breaking capacity ensures safety in fault scenarios.
  • Compact, modular design for efficient space utilization in panels.

Cons

  • IP20 rating restricts use to dry, indoor environments.
  • Limited DC voltage support (125V) compared to some specialized breakers.
  • Requires specific knowledge for correct installation and wiring.
  • Not designed for environments with high humidity or potential water exposure.

Setup, Compatibility & Care

Setup:

The ABB S203-B10 is designed for installation in standard DIN rail enclosures. Ensure the enclosure provides adequate ventilation and protection against environmental factors. Before installation, disconnect all power to the circuit. Mount the breaker securely onto the DIN rail. Connect the incoming power conductors to the designated terminals and the outgoing load conductors to the corresponding terminals. Pay close attention to the pole identification and ensure correct wiring for your specific AC or DC application. Refer to the device's markings for correct terminal connections.

Compatibility:

This breaker is compatible with additional equipment such as auxiliary switches and signal contacts, which can be mounted on the left side. It is designed to fit standard distribution boards and panel systems that accommodate 3 modular width units (52.5mm).

Care:

  • The S203-B10 is virtually maintenance-free under normal operating conditions.
  • Keep the area around the breaker clean and free from dust and debris.
  • Periodically inspect the breaker and its connections for any signs of damage, overheating, or loose wiring.
  • Ensure the ambient temperature remains within the specified operating range (-25 to 55°C).
  • Do not attempt to open or repair the breaker unit; if faulty, it must be replaced.