WAGO 750 Series Analog Input And Output Module - 750-530




Best current price£89.90from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Wago Fieldbus, Decentralized Peripheral - Analog Input And Output Module - 750-530
Visit shop



Best current price£89.90from Tameson UK
Shopping.co.uk recommended and popular offers
Wago Fieldbus, Decentralized Peripheral - Analog Input And Output Module - 750-530
Visit shop3 offers from £89.90 - £217.70
View price history by clicking the chart icon.
3 offers from £36.16 - £58.82
View price history by clicking the chart icon.
The WAGO 750-530 is a fieldbus module designed for industrial automation applications, offering 8 digital output channels for controlling connected loads. It is ideal for systems requiring reliable switching and isolation between field and system levels. A key benefit is its compact size and short-circuit protection on all outputs, though users should note its IP20 rating means it's not suitable for wet environments without additional enclosure.
| Brand | WAGO |
|---|
The module supports a maximum of 0.5 A per channel.
No, the module has an IP20 rating, meaning it is protected against solid objects larger than 12.5mm but offers no protection against water. It should be installed in a suitable enclosure if exposed to moisture.
The module requires a 24 V DC supply voltage.
It means the module provides 0.5 kilovolts of electrical isolation between the field side (connected loads/actuators) and the system side (control system/PLC), helping to protect the control system from voltage spikes or ground loops.
Yes, it features explosion protection for ATEX gas-Ex security, making it suitable for certain hazardous environments.
The connected loads are switched via digital output signals from the control system.
The module measures 12 mm (width) x 100 mm (depth) x 67.8 mm (height).
Verify 24V DC supply voltage is present and correct. Check wiring connections to the control system and loads. Ensure the control system is sending the correct digital signal.
Confirm correct installation on the carrier rail and proper bus connection. Check fieldbus addressing and configuration settings in the control system software.
Ensure ventilation slots are unobstructed. Check if the connected load exceeds the 0.5A per channel limit. Verify ambient temperature is within operational limits.
Disconnect the load from the affected output. Inspect the load and wiring for shorts. Once the fault is cleared, reset the module or control system to resume operation.