APC Metered-by-Outlet Rack PDU 2G - Black

APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power meterin...

Currently unavailable

Currently out of stock

This product is not available at the moment. Check back later.

Product Information

Full details

The APC Rack PDU 2G, Metered-by-Outlet is designed for data center managers and IT professionals seeking granular control and visibility over power usage in rack-mounted environments. Its key benefit is enabling energy optimization and circuit protection through individual outlet power metering, helping to reduce total cost of ownership. A potential caveat is the need for a 400V nominal input voltage, which may not be standard in all environments. This PDU offers real-time remote monitoring of connected loads, supports vertical zero-U mounting, and features 24 outlets (21x C13, 3x C19).

All features

ColourBlack
Model Part NumberAP8481
BrandA.P.C.

Extended Product Information

FAQs

What is the primary benefit of 'Metered-by-Outlet' PDU?

The 'Metered-by-Outlet' feature allows for granular power monitoring at each individual outlet, providing detailed insights into the energy consumption of specific devices connected to the PDU. This enables better load balancing, capacity planning, and energy optimization.

What type of input power connection does this PDU require?

This PDU requires a 400V nominal input voltage and uses an IEC 309 16A 3P+N+PE or IEC 309 20A 3P+N+E power plug.

How many outlets does this PDU have and what types are they?

This PDU has a total of 24 AC outlets: 21 are C13 couplers and 3 are C19 couplers.

Can this PDU be managed remotely?

Yes, this PDU can be accessed and configured through secure Web, SNMP, or Telnet interfaces, allowing for remote monitoring and management.

What is the physical form factor of this PDU?

It is a Zero U (0U) rack capacity PDU, designed for vertical mounting within a standard server rack, thus saving valuable rack space.

What environmental conditions can this PDU monitor?

The PDU includes a port for connecting an external temperature and humidity sensor, allowing you to monitor environmental conditions within the rack.

What certifications does this PDU comply with?

It complies with various certifications including EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL, VDE, and REACH. It is also RoHS compliant.

Troubleshooting

PDU not powering on

Verify the power cord is securely connected to both the PDU and the power source. Ensure the power source is providing the correct voltage (400V nominal) and current (16A/20A). Check the circuit breaker on the PDU and ensure it is in the 'on' position.

Unable to access Web/SNMP/Telnet interface

Confirm the PDU is connected to the network. Verify the IP address configuration for the PDU and ensure it is within your network's range. Check network cabling and switch port status. Consult the PDU's manual for default IP settings if necessary.

Outlet power is not being delivered

Check if the circuit breaker for the relevant bank of outlets has tripped. Ensure the connected device is functioning correctly and its power cable is fully inserted into the PDU outlet. Verify the PDU is receiving adequate power.

Inaccurate power readings

Ensure all connected devices are properly plugged into the outlets. Check that the PDU firmware is up to date. If issues persist, contact APC support as calibration might be needed.

Temperature/Humidity sensor not reporting data

Ensure the sensor is correctly plugged into the designated port on the PDU. Verify the sensor itself is functional and compatible with the PDU model. Check sensor readings via the management interface.

Pros and Cons

Pros

  • Granular power monitoring at the outlet level.
  • Facilitates energy optimization and cost reduction.
  • Space-saving Zero U vertical mounting.
  • Robust remote management capabilities (Web, SNMP, Telnet).
  • Secure connections with locking IEC receptacles.
  • Provides environmental monitoring through sensor port.

Cons

  • Requires a 400V nominal input voltage.
  • Setup may require IT expertise for network configuration.
  • Physical size might be restrictive for certain rack configurations.
  • Primarily focused on data center environments; may be overkill for smaller setups.
  • Relies on external management platforms for advanced features.

Setup, Compatibility & Care

Setup: The PDU is designed for vertical, Zero U mounting within standard server racks. Connect the IEC 309 power plug to a compatible power source (16A or 20A, 400V 3P+N+PE/3P+N+E). Connect your IT equipment to the C13 and C19 outlets. For remote management, connect the PDU to your network via its management interface and configure its IP address using the Web, SNMP, or Telnet interface. Ensure the network is appropriate for the PDU's management protocols.

Compatibility: This PDU is compatible with most standard 19-inch server racks due to its Zero U mounting. It requires a 400V nominal input voltage and utilizes IEC C13 and C19 connectors for output. It integrates with APC's InfraStruxure Central, Operations, Capacity, and Energy Efficiency management platforms.

Care: Keep the PDU clean by wiping it with a dry or slightly damp cloth. Ensure ventilation openings are clear of dust and debris. Regularly check the power connections for any signs of wear or damage. Periodically review power consumption data and environmental sensor readings to ensure optimal performance and prevent potential issues.