Schneider Electric Motor Circuit Breaker - GV2RT07 - 1.6-2.5A

This three-phase motor circuit breaker from Schneider Electric is designed for high inrush current...

Best current price£72.49from Tameson UK

All Offers

6 offers from £72.49 - £212.45

View price history by clicking the chart icon.

Tameson UKSchneider Electric Tesys Gv2rt05 Motor Circuit Breaker 0.63-1A 690V - Gv2rt05
Free delivery in 1–3 days
£72.49
Visit shop
eBayTeSys Deca Motor Switch 3P 75KW 1.6-2.5A GV2RT07
£11.00 delivery
£139.43
Visit shop

Used Offers

5 offers from £17.21 - £99.30

View price history by clicking the chart icon.

eBayTelemecanique Motor Circuit Breaker GV2-RT10 4-6.3 A
£30.13 delivery
£17.21
Visit shop

Product Information

Full details

This Schneider Electric Motor Circuit Breaker (GV2RT07) is designed for three-phase motor protection in applications up to 0.75kW at 400V, particularly those with high inrush current and transformer protection needs. Its key benefit is reliable thermal-magnetic protection, ensuring safety and operational continuity. A potential caveat is its specific current range (1.6-2.5A), requiring careful selection for the intended motor load. Key features include adjustable thermal and fixed magnetic trip settings, high breaking capacity, and robust screw terminal connections, all compliant with international standards.

All features

SeriesGV2R
Model Part NumberGV2RT07
BrandSchneider Electric

Extended Product Information

FAQs

What is the maximum motor power this breaker can protect?

This breaker is rated for motor applications up to 0.75kW at 400V.

What does 'thermal-magnetic protection' mean?

It means the breaker uses a thermal element to protect against overloads (slow increases in current) and a magnetic element to protect against short circuits (sudden, high surges of current).

How do I adjust the current setting?

The breaker has an adjustable current range of 1.6-2.5A. Refer to the specific product manual for instructions on how to adjust the setting, typically involving a dial or screw mechanism.

Can this breaker be used for single-phase motors?

This breaker is designed for three-phase motor applications. Using it for single-phase motors may not provide adequate or correct protection.

What is the magnetic trip level?

The magnetic trip level is fixed at 20 times the nominal current (20xIn), designed to provide rapid protection against short circuits.

What standards does this product comply with?

It complies with major international standards including IEC, UL, and CSA.

Is this breaker suitable for frequent switching applications?

The breaker is certified for 100,000 AC-3 switching cycles, indicating good durability for common industrial switching frequencies, but extremely high-cycle applications might require different solutions.

Troubleshooting

Breaker trips immediately upon power-up

Verify motor wiring for short circuits. Ensure the adjustable current setting is not too low for the motor's startup current. Check for an internal fault within the breaker.

Breaker trips during normal operation

The motor may be overloaded or experiencing frequent starts. Check the motor's load and operating conditions. Adjust the thermal trip setting to the motor's correct FLA if it was set incorrectly. Inspect for worn motor components.

Breaker will not reset after tripping

Ensure the fault condition that caused the trip has been cleared. If the breaker has tripped due to a severe fault, it may need replacement. Check for physical damage to the reset mechanism.

Overheating at terminals

Ensure the supply and load wires are properly sized for the current and that all screw terminal connections are tightened securely. Loose connections generate heat.

Pros and Cons

Pros

  • Provides robust thermal-magnetic protection for three-phase motors.
  • Adjustable trip settings allow for precise motor protection.
  • High breaking capacity ensures safety during fault conditions.
  • Suitable for high inrush current applications and transformer protection.
  • Compliant with major international standards (IEC, UL, CSA).

Cons

  • Specific current range (1.6-2.5A) may not suit all motor sizes.
  • Requires manual reset after a trip.
  • Installation requires appropriate electrical knowledge and safety precautions.

Setup, Compatibility & Care Instructions

Setup: Ensure power is completely disconnected before installation. Mount the GV2RT07 breaker according to its installation instructions, typically within an electrical enclosure. Connect the three-phase power supply to the input terminals and the motor leads to the output terminals using the screw terminals. Ensure all connections are tight and secure. The adjustable current setting should be configured to the motor's full load amperage (FLA) within the 1.6-2.5A range, with the magnetic trip typically set at 20 times the nominal current.

Compatibility: This breaker is designed for three-phase AC motor loads up to 0.75kW at 400V. It is compatible with systems conforming to IEC, UL, and CSA standards. Ensure the ambient temperature and environmental conditions are within the breaker's operating specifications.

Care: Regular visual inspection for dust or debris is recommended. Ensure ventilation around the breaker is clear. No user-serviceable parts are inside; cleaning should be done with a dry or slightly damp cloth. Avoid using solvents. Periodically check terminal connections for tightness, especially after periods of vibration or significant temperature cycling.