Victron Energy MultiPlus-II - 48/10000/140-100 230V

The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the feature...

Best current price£1,399.99from eBay

All Offers

3 offers from £1,399.99 - £1,599.99

View price history by clicking the chart icon.

eBayVictron MultiPlus-II 10kVA 48V inverter 140A AC charger (48/10000/140-100 230V)
Free delivery in 1–3 days
£1,399.99
Visit shop
Butler TechnikVictron Multiplus-Ii 48/10000/140-100 230V
Free delivery in 1–3 days
£1,519.20
Visit shop
OnBuy.comVictron Energy Multiplus-Ii 48/10000/140-100 Sine Power Inverter Battery Charger 8719076044956
Free delivery in 1–3 days
£1,599.99
Visit shop

Product Information

Full details

This guide is for users of the Victron Energy MultiPlus-II, a versatile inverter/charger. It offers the combined functionality of a MultiPlus and MultiGrid, providing power control and assist features. However, users should be aware of the specific installation requirements and compatibility to ensure optimal performance. This guide will walk you through the key features, setup, and troubleshooting for the Victron Energy MultiPlus-II.

All features

Model Part NumberPMP483105000
BrandVictron Energy

Extended Product Information

FAQs

What is the input voltage range?

The input voltage range is 38 - 66 V.

What is the output power?

The output power is 8000 W.

Does the MultiPlus-II support PowerControl and PowerAssist?

Yes, with the use of an external current transformer.

Can I use this device in a grid-connected system?

Yes, it is designed for grid-connected systems and has grid-tie capabilities, as well as off-grid functions.

What kind of batteries are compatible?

The MultiPlus-II is compatible with a wide range of battery types, including lithium-ion and lead-acid.

How do I monitor the device?

You can monitor the device using the VictronConnect app or a GX device.

What certifications does the MultiPlus-II have?

It is certified with EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2, EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3.

Troubleshooting

Device won't turn on.

Check the DC input (battery) connections and ensure the battery is charged. Verify the AC input breaker is on.

Low output voltage.

Check the battery voltage. Low battery voltage can result in low output voltage. Check the AC output connections and settings.

Error messages on the display.

Consult the user manual for specific error codes and troubleshooting steps. Check the AC input, AC output, and DC input connections.

Device overheating.

Ensure adequate ventilation around the device. Reduce the load on the device, and check ambient temperature.

Not charging batteries.

Check the battery settings in the configuration. Verify the solar charge controller connection if applicable.

Pros and Cons

Pros

  • Combines multiple functionalities into a single device, simplifying system design.
  • Offers advanced power management features, including PowerControl and PowerAssist.
  • High efficiency reduces energy waste and lowers operational costs.
  • Built-in safety features like anti-islanding enhance system protection.
  • Ethernet connectivity enables remote monitoring and control.
  • Wide input voltage range provides flexibility in various applications.

Cons

  • Requires professional installation due to the complexity of the device.
  • External current transformer needed for PowerControl and PowerAssist functionality.
  • Size and weight may be a consideration for certain installations (49 kg).
  • Requires careful consideration of external components to ensure system compatibility.

Setup, Compatibility & Care

Setup

  1. Installation: The MultiPlus-II must be installed by a qualified electrician.
  2. Wiring: Connect the AC input, AC output, DC input (battery), and any optional components (e.g., current transformer, generator).
  3. Configuration: Configure the device using the VictronConnect app or a GX device. This includes setting the input voltage range, output voltage, and other parameters.
  4. Testing: After installation, thoroughly test the system to ensure it is functioning correctly.

Compatibility

  • Batteries: Compatible with a wide range of battery types, including lithium-ion and lead-acid. Ensure the battery voltage matches the MultiPlus-II's input voltage.
  • Solar Charge Controllers: Can be integrated with Victron MPPT solar charge controllers for a complete off-grid or grid-tied system.
  • Generators: Can be used with a generator for backup power. Ensure the generator's output matches the MultiPlus-II's specifications.
  • Grid: Can be used in grid-connected systems, adhering to local regulations.

Care

  • Ventilation: Ensure adequate ventilation around the device to prevent overheating.
  • Cleaning: Clean the device with a dry cloth as needed. Do not use solvents or abrasive cleaners.
  • Inspection: Regularly inspect the wiring and connections for any signs of damage or wear.
  • Firmware Updates: Keep the firmware up to date to benefit from the latest features and improvements.