Siemens SIRIUS Timer Relay - DPNO - 3RP2576-1NW30

This electronic timing relay is designed for motor startup control in star-delta circuits. It feat...

Best current price£70.58from eBay

All Offers

2 offers from £70.58 - £72.28

View price history by clicking the chart icon.

eBaySiemens Time Relay 3RP2576-1NW30 3s-60s V1.05 12-240V AC/DC
£30.13 delivery
£70.58
Visit shop
Tameson UKSiemens Sirius 3Rp25 Star Delta Timer Relay - 3Rp25761nw30
Free delivery in 1–3 days
£72.28
Visit shop

Product Information

Full details

The Siemens 3RP2576-1NW30 is an electronic timing relay designed for industrial applications, specifically for controlling motor startup in star-delta circuits. It offers precise timing control with adjustable delay and an instantaneous contact, providing a key benefit of reliable and efficient motor operation. A potential caveat is its specific application focus, requiring users to ensure it meets their precise circuit needs.

All features

SeriesDPNO
Model Part Number3RP2576-1NW30
BrandSiemens

Extended Product Information

FAQs

What is the primary function of this Siemens timing relay?

This relay is specifically designed for controlling the start-up sequence of motors in a star-delta configuration. It manages the transition from the star winding connection to the delta connection.

What is the adjustable time range for the delayed contact?

The delayed contact can be set to operate anywhere between 3 and 60 seconds.

What voltage ranges does this relay support?

It supports a wide operating voltage range of 12V to 240V AC or DC at 50/60Hz.

How many contacts does this relay have, and what types are they?

It features two contacts: one Normally Open (NO) delayed contact and one Normally Open (NO) instantaneous contact.

What is the physical width of the relay?

The relay has a compact width of 22.5mm, making it suitable for space-saving installations in control panels.

Can this relay be used for general-purpose timing?

While it has timing functionality, its design is optimized for star-delta motor starting. For general-purpose timing, other Siemens relays in the SIRIUS range might be more suitable.

How do I reset the relay?

The relay typically resets automatically once the control voltage is removed and reapplied, or when the controlled process reaches its next stage. Specific reset behavior depends on the overall circuit design.

Troubleshooting

Relay does not power on (LED off)

Verify that the control voltage (12-240V AC/DC) is correctly applied to the power terminals (e.g., A1/A2) and that the voltage is within the specified range. Check for loose wiring connections.

Delayed contact does not switch after set time

Confirm that the control voltage is present. Ensure the time adjustment knob is set to a desired value and not at its minimum or maximum if not intended. Check if the contacts are wired correctly in the control circuit.

Instantaneous contact remains open or closed

Ensure the relay is receiving control power. Verify the wiring to the instantaneous contacts (e.g., 5-6) is correct and that the relay is not mechanically obstructed.

Relay switches too early or too late

Recalibrate the time delay setting by carefully adjusting the front knob. Ensure the knob is making positive contact and is not between marked intervals.

Pros and Cons

Pros

  • Reliable motor startup control in star-delta configurations.
  • Adjustable timing provides operational flexibility.
  • Compact 22.5mm width saves space in control cabinets.
  • Wide voltage range (12-240V AC/DC) for diverse power systems.
  • Clear LED indication for easy monitoring.

Cons

  • Primarily designed for star-delta applications; may not be suitable for other timing functions.
  • Requires understanding of star-delta motor starting principles for proper implementation.
  • Screw terminals require proper torque for secure connections.

Setup, Compatibility & Care

Setup:

  1. Mounting: Install the relay onto a standard DIN rail (35mm) in the control panel. Ensure it clicks securely into place.
  2. Wiring: Connect the power supply to the appropriate terminals (e.g., A1/A2 for control voltage). Wire the motor control circuit according to the star-delta schematic, utilizing the NO delayed (e.g., 7-8) and NO instantaneous (e.g., 5-6) contacts as required by your specific motor starter configuration. Ensure all connections are made to the correct terminals as per the wiring diagram on the relay or in its manual. Use appropriate wire gauges and torque settings for the screw terminals.
  3. Time Setting: Adjust the desired delay time for the star-to-delta transition using the rotary knob on the front of the relay, typically ranging from 3 to 60 seconds.

Compatibility:

  • Voltage: Compatible with AC/DC power sources from 12V to 240V at 50/60Hz. Verify your supply voltage matches the relay's operational range.
  • Control Systems: Suitable for integration into standard industrial control circuits, PLCs, and motor starter assemblies.
  • Environment: Designed for industrial environments. Avoid locations with excessive moisture, dust, or extreme temperatures outside its operating specifications.

Care:

  • Cleaning: Keep the relay clean by wiping it with a dry or slightly damp cloth. Avoid using solvents or abrasive cleaners.
  • Ventilation: Ensure adequate ventilation around the relay within the control panel to prevent overheating.
  • Inspection: Periodically check wiring connections for tightness and signs of wear.