This earth leakage circuit breaker from ABB Haf's DS201 series has a total of 2 poles, one of whic...This earth leakage circuit breaker from ABB Haf's DS201 series has a total of 2 poles, one of which is protected (1p+n). In addition, the ground fault circuit breaker is equipped with overcurrent protection (RCBO) for protection against short circuit currents, overloads, ground fault currents, indirect contacts and additional protection against direct contacts. The earth leakage circuit breaker has a rated voltage of 230V, a rated current of 16A, a breaking capacity of 10kA and a rated fault current of 30mA. EAN: 8012542592815 - manufacturer-number: DS201MA-C16/0,03 - Earth leakage circuit breaker C16/0A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated current 16A, Rated fault current 0A, Leakage current type A, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 15kA, Surge current capacity 0kA, Voltage type AC, Frequency 50/60 Hz, Release characteristic C, Concurrently switching N-neutral, Over voltage category 3, Pollution degree 2, Ambient temperature during operating 55 ... 55°C, Width in number of modular spacings 2, Built-in depth 69mm, Degree of protection (IP) IP2X - DS201MA-C16/0,03
Best current price£71.87from Rapid Online - Rapid Electronics Ltd.
The ABB DS201 is a Residual Current Circuit Breaker with Overcurrent protection (RCBO) designed for single-phase circuits in residential and commercial settings. It provides comprehensive protection against overloads, short circuits, and various types of earth faults, offering enhanced safety for electrical installations. While highly effective, its Type A leakage current detection is specific to AC and pulsating DC faults, and may not detect pure DC leakage currents.
All features
Series
DS201
Model Part Number
2CSR275180R1164
Brand
ABB
Extended Product Information
FAQs
What is the difference between an RCBO and an RCD or MCB?
An MCB (Miniature Circuit Breaker) protects against overcurrents (overloads and short circuits). An RCD (Residual Current Device) protects against earth leakage currents. An RCBO (Residual Current Circuit Breaker with Overcurrent protection) combines both functions in a single device, offering protection against overcurrents and earth leakage.
What does 'Type A' leakage current detection mean?
Type A RCBOs are sensitive to sinusoidal alternating earth fault currents and pulsating direct earth fault currents. They are more versatile than Type AC RCBOs but do not detect pure direct current (DC) leakage faults.
What is the significance of the 'C' type release characteristic?
The 'C' type release characteristic indicates that the circuit breaker is designed to withstand moderate inrush currents without tripping. This makes it suitable for circuits with inductive loads, such as motors or lighting ballasts, which can draw higher currents momentarily upon startup.
Can I use the DS201 for a DC circuit?
No, the ABB DS201 is designed exclusively for AC circuits. Using it on DC circuits can lead to incorrect operation or failure to protect.
What is the rated short-circuit breaking capacity?
The rated short-circuit breaking capacity (e.g., 10kA or 15kA) is the maximum fault current the device can safely interrupt without being destroyed. It is crucial that this rating is higher than the potential prospective fault current at the installation point.
How often should I test the RCBO?
It is recommended to test the earth leakage function of an RCBO at least once every six months, or monthly as per some regulations, using the built-in test button. This ensures the residual current detection mechanism is operational.
What is the IP rating of this device?
The DS201 typically has an IP20 rating for finger protection at the terminals and can be part of an installation with higher protection (e.g., IP40) when housed within an appropriate enclosure.
Troubleshooting
Circuit breaker trips immediately upon power restoration
This indicates a persistent fault, likely a short circuit or a significant earth leakage in the connected circuit or appliance. Disconnect all loads and re-energize. If it still trips, there is a fault in the wiring. If it does not trip with loads disconnected, reconnect loads one by one to identify the faulty appliance or circuit.
Circuit breaker trips intermittently
Intermittent tripping can be caused by minor earth leakages (e.g., from damp environments or aging insulation), minor overloads, or faulty connections. Check for loose wiring, inspect appliances for damage, and consider if the circuit is overloaded. For earth leakage, test individual appliances or sections of wiring.
Device does not trip when the 'Test' button is pressed
The earth leakage detection function may be faulty. Do NOT rely on this device for earth leakage protection. Immediately replace the unit and have the circuit inspected by a qualified electrician.
Device trips during thunderstorms or power surges
External events like lightning strikes can induce surges that may cause nuisance tripping. While the DS201 offers some surge immunity, severe surges can still trigger it. Consider installing a whole-house surge protector upstream if this becomes a frequent issue.
Pros and Cons
Pros
Provides comprehensive protection against overload, short circuit, and earth leakage faults in a single device.
Compact two-module design saves valuable space in electrical panels.
High breaking capacity ensures safety during significant fault events.
Reliable performance for AC and pulsating DC earth fault detection.
Durable construction suitable for various environmental conditions.
Cons
Type A leakage detection does not protect against pure DC fault currents.
Requires professional installation by a qualified electrician.
Limited to single-phase applications.
Specific trip curve (Type B) may not be suitable for all load types without careful consideration.
Setup, Compatibility & Care
Setup:
Installation of the ABB DS201 must be performed by a qualified electrician in accordance with local electrical codes and regulations. The device is designed to be mounted on a standard DIN rail (35mm) within an electrical distribution board. Ensure the incoming power supply is de-energized before commencing installation. Connect the line conductor to the designated input terminal and the neutral conductor to its terminal. The outgoing load conductors are then connected to the respective output terminals.
Compatibility:
Voltage: Compatible with standard 230V AC single-phase power supplies.
Frequency: Operates on 50/60 Hz frequency inputs.
System Type: Suitable for TN and IT earthing systems (check specific product documentation for IT system requirements).
Wiring: Designed for circuits requiring both overcurrent and earth leakage protection.
Distribution Boards: Fits within standard modular distribution boards, occupying two modules.
Care and Maintenance:
Cleaning: Keep the device clean and free from dust and debris. Use a dry or slightly damp cloth for cleaning. Never use solvents or abrasive cleaners.
Testing: It is recommended to test the earth leakage function regularly (e.g., monthly) by pressing the 'Test' button on the device. This ensures the RCD mechanism is functioning correctly.
Inspection: Periodically inspect the device and its connections for any signs of damage, overheating, or corrosion. Ensure all connections remain tight.