Finder Installation Relay - 22 Series - 20A - 24VAC
Compact 17.4mm installation relay featuring one NO and one NC contact rated at 20A/250VAC. Feature...Compact 17.4mm installation relay featuring one NO and one NC contact rated at 20A/250VAC. Features 24VAC coil voltage with AgSnO2 contact material. Designed for DIN rail mounting with screw terminals. Suitable for HVAC, lighting, and commercial applications with 5000VA AC1 rating. Includes manual test button and offers 4kV isolation between coil and contacts. EAN: 8012823124537 - manufacturer-number: 22.23.8.024.4000 - Installation relay 24VAC Function Mechanical, Mounting method DIN rail, Width in number of modular spacings 1, Built-in depth 58,4mm, Number of contacts as normally open contact 1, Number of contacts as normally closed contact 1, Number of contacts as change-over contact 0, Control voltage 1 24 ... 24V, Type of control voltage 1 AC, Frequency control voltage 1 50 ... 60Hz, Rated current 20A, Supply voltage 24 ... 24V, Voltage type of supply voltage AC, Max. incandescent lamp load 1000W, Max. load fluorescent lamp 400VA, Max. load fluorescent lamp (Duo circuit) 400VA, Max. load fluorescent lamp (parallel compensated) 360VA, Max. switching current (cos phi = 0.6) 12A - 22.23.8.024.4000 Finder, 24V ac Coil Non-Latching Relay SPST-NC, SPST-NO, 20A Switching Current DIN Rail, 3 Pole, Coil Power: 3W, Coil Resistance: 41 Ω, Isolation Coil To Contact: 4kV, Terminal Type: Screw, Maximum Switching Voltage (AC): 250V ac, Depth: 58.4mm, Height: 84mm, Maximum Switching Power (AC): 5 kVA, Series: 22 Series, MPN: 22.23.8.024.4000
Best current price£17.09from Rapid Online - Rapid Electronics Ltd.
This Finder Installation Relay (22 Series, MPN: 22.23.8.024.4000) is designed for professionals in HVAC, lighting, and commercial applications needing a reliable switching solution. Its key benefit is a high 20A switching capacity in a compact DIN rail mountable package with a 24VAC coil. A potential caveat is its AC-only coil voltage, requiring a specific AC power source.
All features
Series
22 Series
Model Part Number
22.23.8.024.4000
Brand
Finder
Extended Product Information
FAQs
What is the AC1 rating for this relay?
The relay has an AC1 rating of 5000VA, which is suitable for resistive loads.
Can I use this relay with a DC control voltage?
No, this relay is specifically designed for a 24VAC coil voltage and is not compatible with DC control voltages.
How do I test the relay without energizing the coil?
The relay features a manual test button that allows you to manually operate the contacts for testing purposes without applying voltage to the coil.
What is the maximum switching current for inductive loads?
For loads with a power factor of 0.6 (typical for fluorescent lamps or motors), the maximum switching current is rated at 12A.
What type of contact material does this relay use?
It uses AgSnO2 (Silver Tin Oxide) contact material, which offers good performance and durability.
Can this relay be mounted on a standard electrical panel?
Yes, it is designed for mounting on a standard 35mm DIN rail, commonly found in electrical panels.
What is the isolation voltage between the coil and contacts?
The relay provides 4kV (4000 Volts) of isolation between the coil and the contacts for enhanced safety.
Troubleshooting
Relay does not energize when control voltage is applied
Verify the control voltage is exactly 24VAC and within the specified frequency. Check wiring to the coil terminals (A1/A2) for secure connection and correct polarity if applicable (though AC coils are not polarity sensitive). Ensure the control circuit is functional.
Contacts are not switching (stuck open or closed)
Ensure the coil is correctly energized with 24VAC. If the issue persists after confirming coil voltage, the contacts may be damaged or welded. Test using the manual test button; if it functions, the issue is with the coil activation. If the manual test also fails, the relay may need replacement.
Relay buzzes or hums loudly
This could indicate an unstable or incorrect AC voltage supply to the coil. Check the stability and accuracy of the 24VAC supply. Ensure the frequency is within the 50-60Hz range.
Overheating at terminals
Ensure the connected wires are of appropriate gauge for the current being switched. Tighten screw terminals securely. If overheating continues, the load current may exceed the relay's rating or the wire size is insufficient.
Pros and Cons
Pros
High current handling capacity (20A).
Compact 17.4mm width saves panel space.
Provides both NO and NC contacts for flexible wiring.
Includes a manual test button for easy testing.
Good isolation rating (4kV) for safety.
Cons
Limited to 24VAC coil voltage, not suitable for DC systems.
AC1 rating limits its suitability for highly inductive loads compared to AC3 ratings.
Single pole configuration (one NO, one NC) might require multiple units for more complex switching.
Requires precise wiring to DIN rail and terminals.
Setup, Compatibility & Care
Setup:
Mounting: Snap the relay onto a standard 35mm DIN rail. Ensure it is securely fixed.
Wiring: Connect the control circuit to the coil terminals (typically marked A1/A2 for the 24VAC coil). Connect the load circuit to the appropriate NO/NC and common terminals. Use screw terminals for secure connections. Refer to the terminal markings on the relay for correct configuration.
Power: Ensure the control voltage supply is stable at 24VAC and within the specified frequency range (50-60Hz).
Compatibility:
Coil Voltage: Primarily compatible with 24VAC control systems. Not directly compatible with DC control voltages.
Load Type: Suitable for resistive loads (AC1 rating) up to 20A. For inductive loads (like motors, fluorescent lamps), derating may be necessary (e.g., 12A max switching current for cos phi = 0.6).
Mounting: Requires a standard 35mm DIN rail.
Care:
Cleaning: Keep the relay free from dust and debris. Use a dry or slightly damp cloth for cleaning. Avoid using solvents.
Environment: Operate within the specified temperature and humidity ranges to ensure longevity.
Inspection: Periodically check wiring connections for tightness and signs of overheating.