GW Instek Function Generator - SFG-1013

The SFG GW Instek SFG-1013 is an economic function generator with high accuracy and high stability...

Best current price£186.74from OnBuy.com

All Offers

2 offers from £186.74 - £194.05

View price history by clicking the chart icon.

OnBuy.comGw Instek Sfg-1013 Dds Function Generator 4719692504982
Free delivery in 1–3 days
£186.74
Visit shop
eBayGW Instek DDS Function Generator
Free delivery in 1–3 days
£194.05
Visit shop

Product Information

Full details

The GW Instek SFG-1013 is an economic function generator designed for users requiring accurate and stable signal outputs for basic measurement applications. It leverages DDS technology to provide reliable sine, rectangle, and triangle waveforms up to 3MHz, making it a solid choice for educational labs or simple electronics testing. A primary caveat is its limited frequency range and waveform options compared to more advanced models.

All features

Model Part NumberSFG-1013
BrandGW Instek

Extended Product Information

FAQs

What waveforms can the SFG-1013 generate?

The SFG-1013 can generate sine, rectangle, and triangle waveforms.

What is the maximum frequency output?

The maximum frequency output is 3MHz.

Does it have a TTL output?

Yes, the SFG-1013 includes a dedicated TTL output.

Is this generator suitable for complex signal modulation?

No, this model is designed for basic signal generation and does not support complex modulation features.

How accurate is the frequency output?

The SFG-1013 provides high accuracy and stability due to its DDS technology, suitable for its intended applications.

What type of connector does the output use?

The output uses a standard BNC connector.

Can I generate arbitrary waveforms with this model?

No, this model is limited to sine, rectangle, and triangle waveforms. Arbitrary waveform generation requires more advanced function generators.

Troubleshooting

No output signal

Ensure the output is enabled, check cable connections, and verify the frequency and amplitude settings are appropriate.

Waveform distortion

Check the load impedance; ensure it is within the generator's specifications. Verify the frequency is not at the extreme upper limit where accuracy might decrease.

Inaccurate frequency reading

Allow the generator to warm up for a few minutes for maximum stability. Ensure the selected frequency is within the specified accuracy range for the instrument.

Unit does not power on

Verify the power cord is securely connected to both the unit and a working power outlet. Check the fuse if applicable.

Pros and Cons

Pros

  • High accuracy and stability due to DDS technology.
  • Cost-effective for budget-conscious users.
  • Provides essential waveform types for basic applications.
  • Compact and easy to operate.
  • Reliable for educational and simple measurement tasks.

Cons

  • Limited to a 3MHz maximum frequency.
  • Only offers sine, rectangle, and triangle waveforms (no arbitrary waveforms).
  • May lack advanced modulation or sweeping features found in higher-end generators.
  • Interface might be basic for complex signal generation scenarios.

Setup, Compatibility & Care

Setup:

  1. Connect the appropriate output cable to the device under test.
  2. Power on the SFG-1013 using the provided power cord.
  3. Select the desired waveform (sine, rectangle, triangle) using the dedicated buttons.
  4. Adjust the frequency using the control knobs to the required value within the 3MHz range.
  5. Set the amplitude using the amplitude control knob.

Compatibility: The SFG-1013 is compatible with standard laboratory test equipment such as oscilloscopes, spectrum analyzers, and multimeters via its BNC output connectors.

Care:

  • Keep the unit in a clean, dry environment.
  • Avoid exposure to extreme temperatures or humidity.
  • Clean the exterior with a soft, dry cloth. Do not use liquid cleaners or solvents.
  • Ensure ventilation slots are not obstructed to prevent overheating.

Price History

DatePrice
Visit shop