Schneider Electric Miniature Circuit Breaker - C60H-DC - 2P 63A

Best current price£56.14from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Schneider Electric Circuit Breaker - A9n61524
Visit shop
Best current price£56.14from Tameson UK
Shopping.co.uk recommended and popular offers
Schneider Electric Circuit Breaker - A9n61524
Visit shop15 offers from £56.14 - £107.35
View price history by clicking the chart icon.
1 offer from £71.82
View price history by clicking the chart icon.
This Schneider Electric Miniature Circuit Breaker (model A9N61539) is designed for professionals requiring robust DC circuit protection. Its key benefit is reliable overcurrent and short-circuit protection for DC circuits up to 500V, with a 20 kA breaking capacity. A potential consideration is its specific DC application, meaning it is not suitable for AC circuits. Key features include its 2-pole design, 63A rating, Type C tripping characteristic, and DIN rail mounting.
| Series | C60H-DC |
|---|---|
| Model Part Number | A9N61539 |
| Brand | Schneider Electric |
No, the Schneider Electric C60H-DC series is specifically designed and rated for DC (Direct Current) circuits only. Using it on AC circuits can lead to malfunction and safety hazards.
Connect the positive (+) conductor to one pole and the negative (-) conductor to the other pole. Ensure correct polarity and that both poles are switched simultaneously.
A Type C breaker trips when the current reaches 5 to 10 times its rated current. This makes it suitable for circuits with moderate inrush currents, such as those powering motors or fluorescent lighting.
The breaking capacity is 20 kA (kiloamperes), meaning it can safely interrupt fault currents up to 20,000 Amperes.
This breaker is suitable for DC circuits requiring a 63A rating, a Type C tripping characteristic, and operating at voltages up to 500V. Always consult your system's electrical design specifications.
Green Premium is Schneider Electric's label for products that are compliant with environmental regulations (like RoHS) and have a low environmental impact throughout their lifecycle.
Yes, due to the nature of electrical work and the specific requirements for DC circuits, professional installation by a qualified electrician is strongly recommended to ensure safety and compliance.
Check for overloaded circuits. Verify the connected load does not exceed the 63A rating. Ensure the Type C tripping characteristic is appropriate for the load's inrush current. Inspect wiring for any short circuits.
Identify and rectify the fault condition (overload or short circuit) that caused the trip. If the fault is cleared and the breaker still won't reset, it may be damaged and require replacement.
This indicates a potentially serious safety hazard. Do not use the circuit. Immediately replace the breaker and have the system inspected by a qualified electrician.
De-energize the circuit immediately. Inspect the terminal connections for looseness and clean any corrosion. Retighten connections securely. If damage is evident, replace the breaker.
Setup:
Compatibility:
Care: