WT Henley House Service Cut Out - 100 Amp

House Service Cut Out. Henley 54138-12 House Service Cut Out Series 7 SP&N 100 Amp (Less Fuse) Ser...

Best current price£25.75from OnBuy.com

All Offers

2 offers from £25.75 - £28.00

View price history by clicking the chart icon.

OnBuy.comHenley 54138-12 House Service Cut Out Series 7 Sp&N, 100A, Fuse Not Included, Bs88, 240/415V Ac 5051140622886
Free delivery in 1–3 days
£25.75
Visit shop
B&QB&Q - Henley 54138-12 House Service Cut Out Series 7 Sp&n 100 Amp (Less Fuse)
Free delivery in 1–3 days
£28.00
Visit shop

Product Information

Full details

This guide is for electricians and technicians who need to understand and work with the WT Henley House Service Cut Out - 100 Amp (model 54138-12). It provides a safe and reliable way to isolate a property's electrical supply. Please note that this unit does not include fuses; appropriate fuses (such as MF63A - 63 amp) must be sourced separately.

All features

Model Part Number54138-12
BrandWT Henley

Extended Product Information

FAQs

What type of fuse does this unit require?

The WT Henley House Service Cut Out - 100 Amp requires fuses, such as the MF63A (63 amp).

Who should install this cut out?

Installation must be carried out by a qualified electrician.

Where is this cut out typically installed?

It is typically installed at the point where the electricity supply enters the property.

What is the purpose of a house service cut out?

It provides a safe means to disconnect the electricity supply to a property for maintenance or emergencies.

Is this cut out suitable for three-phase systems?

No, it is designed for single-phase systems only.

What does SP&N mean?

Single Pole and Neutral.

Troubleshooting

No power to the property.

Check the fuses in the cut out; replace if blown. Check all connections.

The cut out is overheating.

Check the load and connections. Reduce load if necessary. Consult a qualified electrician.

Pros and Cons

Pros

  • Provides a safe point of isolation for electrical services.
  • Durable construction ensures long-term reliability.
  • Designed for standard residential applications.

Cons

  • Fuses are not included and must be purchased separately.
  • Requires professional installation by a qualified electrician.
  • Limited to a 100 Amp capacity.

Setup, Compatibility & Care

Setup:

  1. Installation must be carried out by a qualified electrician, following local regulations and standards.
  2. Ensure the correct size and type of fuse (e.g., MF63A) are installed before connecting the power supply.
  3. Securely mount the unit in a suitable enclosure.
  4. Connect the supply and load cables, ensuring all connections are properly tightened.

Compatibility:

  • This cut out is designed for use in single-phase systems.
  • Compatible with MF63A (63 amp) fuses.

Care:

  • Regularly inspect the unit for any signs of damage or wear.
  • Check the integrity of the cable connections periodically.
  • Do not attempt to repair the unit yourself; contact a qualified electrician if repairs are needed.