Fernox Boiler Noise Silencer - F2 - 500ml

Reduces boiler noise and improves heat transfer efficiency. Ideal for new and existing systems. Ea...

Best current price£24.43from OnBuy.com

One Offer

1 offer from £24.43

View price history by clicking the chart icon.

OnBuy.comFernox 56602 500Ml F2 Boiler Noise Silencer 5014551999794
Free delivery in 1–3 days
£24.43
Visit shop

Product Information

Full details

The Fernox Boiler Noise Silencer F2 is designed for homeowners experiencing boiler noise and seeking improved heating efficiency. Its key benefit is reducing unwanted sounds while optimizing heat transfer. A potential consideration is that it requires proper system draining and refilling for application. This 500ml solution is easy to use and suitable for both new and existing heating systems, helping to maintain optimal boiler performance and quiet operation.

All features

Model Part NumberF2-500ml
BrandFernox

Extended Product Information

FAQs

How long does it take for Fernox F2 to work?

Typically, you should notice a reduction in boiler noise within 24 to 48 hours of circulating the product throughout the heating system.

Can I use Fernox F2 in a system with an electric boiler?

Fernox F2 is designed for domestic central heating systems. While it can be used in systems powered by electric boilers, its primary function is to address noises related to water circulation and heat exchange, which are common in conventional boiler systems.

Is Fernox F2 safe for all types of pipework and radiators?

Yes, Fernox F2 is formulated to be safe for all common metals and materials found in domestic central heating systems, including aluminum.

Do I need to remove Fernox F2 after it has worked?

No, Fernox F2 is a long-term treatment and does not need to be removed unless the system is being completely flushed for other maintenance purposes.

What if my boiler makes a different kind of noise?

Fernox F2 is most effective against noise caused by sludge and poor circulation. If the noise is mechanical or electrical, it may require diagnosis and repair by a qualified heating engineer.

How much Fernox F2 should I add to my system?

For a standard domestic system, the 500ml bottle is sufficient. Ensure you create adequate space by partially draining the system before adding the full contents.

Troubleshooting

Boiler noise persists after application.

Ensure the correct dosage was added and the system was properly circulated. Some severe mechanical noises may not be resolved by chemical treatment; consult a heating engineer.

System pressure drops after adding F2.

Check all connections for leaks, especially around the filling loop and radiators. Ensure radiators have been fully vented and the system is refilled to the correct pressure.

Difficulty introducing the liquid into the system.

Ensure the filling loop is correctly connected and that there is sufficient space in the system by draining an appropriate amount of water beforehand.

Pros and Cons

Pros

  • Effectively reduces common boiler noises.
  • Enhances heating system efficiency.
  • Simple and straightforward application.
  • Works with new and existing systems.
  • Helps protect boiler components.

Cons

  • Application requires draining and refilling the system.
  • Effectiveness may vary based on the cause of the noise.
  • Requires access to the system's filling loop.

Setup, Compatibility & Care

Compatibility:

The Fernox Boiler Noise Silencer F2 is designed for use in all types of domestic central heating systems, including those with aluminum components. It is suitable for both vented and unvented systems.

Setup and Application:

  1. Ensure System is Cool: Before application, make sure the central heating system is cool to the touch.
  2. Drain System: Partially drain the heating system to create space for the additive. The amount to drain depends on the system size, but enough to accommodate the 500ml of F2 is necessary.
  3. Add F2: Using the filling loop, slowly introduce the 500ml of Fernox Boiler Noise Silencer F2 into the system.
  4. Refill and Vent: Refill the system to its normal operating pressure and vent all radiators to remove any trapped air.
  5. Circulate: Turn the heating system back on and allow it to circulate for at least 24-48 hours for the product to work effectively.

Care:

Once added, Fernox F2 does not require removal unless the system is being completely flushed or refilled for other maintenance reasons. It is a long-term treatment. Regularly check system pressure and vent radiators as needed.

Price History

DatePrice
Visit shop