Festo 3/2 NO Monostable Air Solenoid Valve G3/8 2300l/min - 575583

The VUVS air solenoid valve is a robust 3/2 monostable valve with electrical actuation. It offers ...

Best current price£86.00from Tameson UK

One Offer

1 offer from £86.00

View price history by clicking the chart icon.

Tameson UKFesto 3/2 No Monostable Air Solenoid Valve G3/8 2300L/Min - 575583
Free delivery in 1–3 days
£86.00
Visit shop

Product Information

Full details

This guide is for industrial automation professionals and technicians working with pneumatic systems. The Festo 3/2 NO Monostable Air Solenoid Valve (575583) provides a durable, cost-effective solution for controlling air flow with a nominal flow rate of 2300 l/min and a G3/8 connection. While its universal design is a significant advantage, users should be aware of its specific 3/2 monostable configuration, which dictates its operational behavior. Key features include electrical actuation, robust construction, and suitability for manifold mounting.

All features

BrandFesto

Extended Product Information

FAQs

What does '3/2 NO Monostable' mean?

It means the valve has three ports (pressure, output, exhaust) and two flow paths (open or closed). 'NO' (Normally Open) typically refers to the state when de-energized, though for 3/2 valves, it describes the flow path between ports when unactuated. 'Monostable' means it has one stable position, returning to that position when the electrical signal is removed.

What is the maximum operating pressure?

Refer to the official Festo datasheet for the specific variant (575583) for precise operating pressure limits, but typically such valves operate up to 10 bar.

Can this valve be used with gases other than air?

This valve is designed for compressed air. Using other gases may require specific seals or certifications and should be confirmed with Festo.

What type of electrical connection does it use?

The electrical connection type depends on the specific solenoid variant. Common types include DIN 43650 connectors or flying leads. Consult the product's specific datasheet for details.

How do I determine if my application requires a Normally Open (NO) or Normally Closed (NC) valve?

A Normally Closed (NC) valve blocks flow when de-energized and opens when energized. A Normally Open (NO) valve allows flow when de-energized and blocks flow when energized. The choice depends on the desired default state of your pneumatic actuator.

Is lubrication required for the compressed air?

This valve is designed to operate reliably with both lubricated and unlubricated compressed air, offering flexibility in system maintenance.

Troubleshooting

Valve does not actuate when signal is applied

Check electrical connections, verify correct voltage supply, and ensure the signal is correctly interpreted by the solenoid. Confirm the solenoid coil is not faulty.

Slow response time or weak actuation

Verify air supply pressure is within the specified range. Check for air leaks in the pneumatic lines or at connections. Ensure the exhaust port (Port 3) is not blocked.

Valve fails to return to its monostable position

Ensure electrical power to the solenoid is completely removed. Check for internal obstructions or damage preventing proper spring return. Verify the air pressure is not holding the valve in the actuated state.

Air leaks from exhaust port (Port 3) when actuated

This is normal operation for the actuated state in a 3/2 valve. If leaking when *not* actuated, check internal seals.

Pros and Cons

Pros

  • Durable construction for industrial applications.
  • High flow rate (2300 l/min) for efficient operation.
  • Versatile for both individual and manifold mounting.
  • Cost-effective for budget-conscious projects.
  • Reliable monostable operation.

Cons

  • Specific 3/2 NO configuration may not suit all pneumatic logic requirements.
  • Requires electrical power for actuation.
  • May require specific manifold base for multi-valve arrangements.
  • Not inherently explosion-proof; suitable for standard industrial environments.

Setup, Compatibility & Care

Setup:

  1. Ensure the air supply is depressurized before installation.
  2. Connect pneumatic lines to the G3/8 ports, ensuring a secure fit. Port 1 is typically the pressure input, Port 2 is the output, and Port 3 is the exhaust.
  3. Connect the electrical actuator according to the specified voltage and wiring diagram.
  4. If using manifold mounting, attach the valve to the appropriate Festo manifold base.
  5. Pressurize the system and test the valve's operation.

Compatibility:

  • Pneumatic connection: G3/8
  • Operating pressure range: Typically 2-10 bar (refer to datasheet for exact specifications).
  • Electrical actuation: Compatible with standard industrial control voltages (e.g., 24V DC, 110V AC, 230V AC - verify specific model variant).
  • Media: Filtered, lubricated or unlubricated compressed air.

Care:

  • Regularly inspect pneumatic connections for leaks.
  • Ensure the compressed air supply is clean and dry to prevent internal component damage.
  • Keep the valve free from excessive dust and debris.
  • Avoid exposing the valve to extreme temperatures or corrosive environments unless specified otherwise.

Price History

DatePrice
Visit shop