Setup, Compatibility & Care
To ensure a successful installation, follow these technical requirements:
- Pipe Preparation: Cut the 15mm copper pipe square and remove all internal and external burrs. Ensure the surface is clean and free from scratches or debris.
- Tooling: Use only calibrated M-profile press jaws. Ensure the jaws are free of grit to prevent scarring of the fitting.
- Insertion: Mark the insertion depth on the copper pipe to verify the pipe is seated fully inside the coupler before pressing.
- Pressing: Align the press jaw squarely over the fitting collar and activate the tool. Do not stop the cycle before completion.
- Maintenance: Periodically inspect installed fittings for signs of corrosion or external damage. Do not reuse fittings once they have been crimped.