Siemens 5SV Residual Current Device - 5SV37466


Best current price£349.40from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Siemens 5Sv Residual Current Device - 5Sv37466
Visit shop

Best current price£349.40from Tameson UK
Shopping.co.uk recommended and popular offers
Siemens 5Sv Residual Current Device - 5Sv37466
Visit shop1 offer from £349.40
View price history by clicking the chart icon.
The Siemens 5SV Residual Current Device (RCD) is designed for professionals needing reliable protection against earth leakage faults in 4-pole electrical systems. Its key benefit is enhanced safety through Type A tripping characteristics, suitable for detecting AC and pulsating DC fault currents. A potential caveat is its specialized application, requiring knowledge of electrical system requirements for proper installation. This 63A, 400V AC device offers 10 kA short-circuit capacity and is built for standard DIN rail mounting.
| Series | 5SV3 |
|---|---|
| Model Part Number | 5SV37466 |
| Brand | Siemens |
An RCD's primary function is to protect people from electric shock by detecting imbalances in current flowing through the live and neutral conductors. If an imbalance is detected (indicating current is leaking to earth), it rapidly cuts off the power supply.
Type A RCDs are sensitive to both sinusoidal AC residual currents and pulsating DC residual currents. This makes them more versatile than Type AC RCDs, which are only sensitive to AC. They are recommended for installations that include electronic equipment like variable speed drives or power supplies.
A 500mA trip sensitivity is typically used for main incoming protection or for protecting installations where the risk of fire due to persistent earth leakage is a concern. It is less sensitive than the 30mA devices often used for direct protection against electric shock.
No, this is a 4-pole device designed for 400V AC systems, typically three-phase. A single-phase installation would require a 2-pole RCD.
The 10 kA short-circuit current rating indicates the maximum fault current the RCD can safely interrupt without being damaged. This rating must be coordinated with the upstream overcurrent protective device (like a circuit breaker).
It is generally recommended to test RCDs monthly using the built-in test button to ensure they are functioning correctly. Always refer to local electrical regulations for specific testing frequencies and procedures.
The mechanical service life is rated at 10,000 switching cycles, meaning the device is designed to operate correctly for this many operations under no-load or rated-load conditions, contributing to its long-term reliability.
This usually indicates an earth fault on the load side of the circuit or a wiring error. Verify all connections are correct and that no equipment connected to the protected circuit has a persistent earth leakage. Disconnect all loads and test again; if it still trips, the RCD may be faulty or there's an issue upstream.
Ensure the device is correctly wired and receiving power. If it still fails, the RCD may be defective and requires replacement by a qualified electrician.
Intermittent tripping can be caused by minor earth leakage currents from multiple sources (e.g., small appliances, long cable runs, humid environments) or voltage surges. Identify and isolate potential leaking loads. Check for damage to wiring or connected equipment. Surge protection devices may be considered if voltage surges are suspected.
Ensure terminals are tightened correctly to the specified torque. Loose connections cause resistance and heat. Check that the connected conductors are of appropriate size for the 63A rating. Ensure adequate ventilation in the enclosure.
Setup: This device is designed for mounting onto a standard 35mm DIN rail within an electrical enclosure. Ensure the main power supply is de-energized before installation. Connect the live conductors to the line terminals and the load conductors to the load terminals, following the correct phase sequence for a 4-pole system. The neutral conductor should be connected to the designated neutral terminal. It is crucial that this installation is performed by a qualified electrician to ensure compliance with safety standards.
Compatibility: The 5SV37466 is compatible with standard 50 Hz AC electrical systems operating at 400V. It is designed to work with wiring systems where its 63A current rating and 10 kA short-circuit rating are appropriate.
Care: As a protection device, the RCD requires minimal direct care. Periodically test its functionality using the integrated test button (if applicable and recommended by local codes). Keep the electrical enclosure clean and well-ventilated to prevent dust accumulation and overheating, which can affect performance and lifespan. Avoid exposing the device to excessive moisture or corrosive environments. The mechanical service life is rated for 10,000 switching cycles; regular testing will help ensure it remains operational.