Schneider Electric Distribution Block - 160A - 13 Connections - LGY116013
This Linergy DS screw distribution block is designed for 4P installations and can be mounted on a ...This Linergy DS screw distribution block is designed for 4P installations and can be mounted on a standard DIN rail or mounting plate. It features 13 connection points with a rated current capacity of 160A. The block is compatible with various cable diameters (9mm, 7.5mm, 6.5mm) and operates at 230VAC (Ph/N) or 440VAC (Ph/Ph). It has an insulation voltage of 500VAC and an impulse voltage of 8kV. The dimensions are 100mm x 126mm x 50.5mm. This terminal block complies with IEC/EN 60947-7-1 and IEC/EN 61439-1 & 2 standards. It is compatible with Prisma G and P, Pragma, Mini Pragma, and Resbo series enclosures. An optional additional neutral terminal block is available for 4-pole distribution blocks.
Acti9 LGY116013 Distribution Block 13-Hole 160A 1P£13.20 delivery£114.56Visit shop →
Prisma Plus G 1P 125A Distribution Block LGY112510£13.20 delivery£133.97Visit shop →
LGY116013 Prisma G LGY Distribution Block 1P 160A 13£13.20 delivery£153.92Visit shop →
Product Information
Full details
The Schneider Electric Linergy DS distribution block (LGY116013) is designed for electricians and installers working on 4-pole electrical installations. Its key benefit is providing a robust and compliant solution for distributing power with 13 connection points and a 160A current rating, mountable on standard DIN rails. A potential caveat is the need for an optional neutral terminal block for specific 4-pole configurations.
All features
Model Part Number
LGY116013
Brand
Schneider Electric
Extended Product Information
FAQs
What is the maximum current rating for this distribution block?
The Schneider Electric Linergy DS distribution block (LGY116013) has a maximum current rating of 160A.
How many connection points does this block have?
This distribution block provides 13 connection points.
Can this block be mounted without a DIN rail?
Yes, in addition to standard DIN rail mounting, it can also be mounted on a mounting plate.
Is a neutral terminal included for 4-pole installations?
For standard 4-pole distribution, an optional additional neutral terminal block is available and may need to be purchased separately.
What cable sizes can be connected?
The block is designed to accommodate minimum cable section of 1.5 mm² and maximum cable section of 25 mm².
What are the operating temperature limits?
The operating temperature range for this distribution block is -25°C to 55°C.
What standards does this product comply with?
It complies with EN/IEC 60947-7-1 and EN/IEC 61439-1 & 2 standards.
Troubleshooting
No power distribution through the block
Verify that the main incoming power supply is active. Check that all conductors are securely terminated in the correct terminals and that screws are tightened properly. Ensure the block is correctly seated on the DIN rail or mounting plate.
Overheating at a terminal
Inspect the specific terminal for loose wire connections or insufficient wire stripping. Ensure the connected cable's cross-sectional area is within the specified range (1.5 mm² to 25 mm²). Verify the total load does not exceed the 160A rating of the block.
Difficulty connecting cables
Confirm that the cable's outer diameter is compatible with the block's connection point specifications. Ensure the cable end is properly stripped to the required length and that no stray strands are present. Do not force cables into terminals.
Pros and Cons
Pros
High current handling capacity (160A) for robust power distribution.
Numerous connection points (13) reduce the need for multiple smaller blocks.
Flexible mounting options (DIN rail or plate) simplify installation.
Wide range of cable diameter compatibility.
Compliant with major international electrical standards.
Cons
An optional neutral terminal block must be purchased separately for certain 4-pole applications.
Maximum cable section is limited to 25 mm².
Specific operational voltage limits (230VAC Ph/N, 440VAC Ph/Ph).
Setup, Compatibility & Care
Setup:
Ensure the power supply is de-energized before installation.
Mount the distribution block onto a standard 35mm DIN rail or a suitable mounting plate using its integrated clips or screw holes.
Connect incoming power conductors to the appropriate terminals.
Connect outgoing circuit conductors to the remaining terminals, ensuring compliance with wire stripping lengths and securing screws firmly.
For 4-pole applications requiring neutral distribution, ensure the optional neutral terminal block is correctly installed.
Compatibility:
Compatible with Schneider Electric enclosures: Prisma G, P, Pragma, Mini Pragma, and Resbo.
Supports cable sizes from 1.5 mm² to 25 mm².
Operational voltage: 230VAC (Ph/N) or 440VAC (Ph/Ph).
Care:
Periodically check terminal connections for tightness, especially after initial installation and under load.
Keep the area around the distribution block clean and free from dust or debris.
Avoid exposure to excessive moisture or corrosive environments.