Warmer 6 Port Underfloor Heating Manifold - 15mm X 3/4

This comprehensive 6-port underfloor heating manifold system provides efficient water distribution...

Best current price£142.95from B&Q

All Offers

7 offers from £142.95

View price history by clicking the chart icon.

B&QB&Q - 6 Port Underfloor Heating Manifold With Pipe Connections Copper 15mm X 3/4 Ball Valves With Thermometers Psw Tradesuppliers Ltd
Free delivery in 1–3 days
£142.95
Visit shop

Product Information

Full details

The Wärmer System 6 Port Underfloor Heating Manifold is designed for efficient water distribution in residential and commercial underfloor heating systems. It offers straightforward integration with its pipe connections and simplified maintenance through isolatings ball valves and an automatic air vent. A potential consideration is ensuring compatibility with your specific piping diameter, as this model is 15mm x 3/4.

All features

Model Part Number6 PORT
BrandWärmer System

Extended Product Information

FAQs

What is the main purpose of this manifold?

This manifold distributes heated water from a central source to multiple, individual underfloor heating loops, allowing for zoned temperature control.

What pipe size does this manifold support?

This specific model is designed for 15mm underfloor heating pipes, with 3/4" connections for the main flow and return.

How do I remove air from the underfloor heating system?

The manifold features an automatic air vent end unit that expels air. You can also use the filling/drain off valve for manual bleeding if necessary.

Can I isolate individual heating zones for maintenance?

Yes, each port has its own main isolating ball valve, allowing you to shut off individual loops without affecting the rest of the system.

How do I monitor the system's performance?

The manifold includes a pressure gauge end unit, which allows you to monitor the system's operating pressure at a glance.

Is this manifold suitable for DIY installation?

The manifold is designed for easy installation with standard plumbing tools. However, basic plumbing knowledge and adherence to safety guidelines are recommended for a successful installation.

What maintenance is required for the manifold?

Regular checks of the pressure gauge and inspection of connections for leaks are recommended. Ensure air vents are functioning correctly.

Troubleshooting

No heat in one or more zones

Check if the isolating ball valve for that zone is open. Ensure there are no airlocks in the circuit; use the automatic air vent or manual bleed points if necessary. Verify the flow rate to that zone is correctly set.

System pressure is too low or too high

Check the pressure gauge. If low, refill the system via the filling/drain off valve. If high, use the drain off valve to release excess pressure, ensuring not to drain the entire system.

Leaking connections

Turn off the water supply to the manifold. Carefully inspect the leaking connection and re-tighten or re-apply appropriate sealant. If the leak persists, the fitting may need replacement.

Air continuously escaping from the automatic air vent

This indicates air is still present in the system. Ensure the system has been fully bled and is holding pressure. Check for potential air ingress points elsewhere in the system.

Pros and Cons

Pros

  • Efficient and balanced water distribution to multiple heating zones.
  • Independent isolation of heating circuits for maintenance.
  • Automated air removal to maintain system efficiency.
  • Clear system pressure monitoring capability.
  • Robust construction for long-term use.

Cons

  • Requires specific pipe size (15mm x 3/4); check compatibility with existing or planned pipework.
  • Requires basic plumbing knowledge for installation and maintenance.
  • Does not include integrated thermostats or actuators (sold separately).
  • Initial setup requires careful system balancing.

Setup, Compatibility & Care Instructions

Setup:

  1. Ensure the manifold is mounted securely in a suitable location, typically near the heat source.
  2. Connect the main flow and return pipes from your boiler or heat pump to the corresponding inlet and outlet ports on the manifold.
  3. Connect the individual heating loops from your underfloor heating pipes to the six available ports. Ensure the pipe size is compatible (15mm x 3/4 for this model).
  4. Connect the automatic air vent and pressure gauge end units as per the diagram.
  5. Use appropriate plumbing fittings and sealants to ensure leak-free connections.
  6. Once plumbing is complete, fill the system via the filling/drain off valve and bleed any air.

Compatibility:

  • This manifold is designed for use with underfloor heating systems.
  • The pipe connections are 15mm for the loops and 3/4" for the main connections.
  • Ensure your boiler or heat pump has sufficient output to manage the total heating load.
  • Compatible with standard plumbing tools and materials.

Care:

  • Periodically check the pressure gauge to ensure it is within the recommended operating range.
  • Listen for any unusual noises that might indicate air in the system; if present, use the automatic air vent or manual bleed points.
  • Inspect all connections annually for signs of leaks.
  • The exterior can be cleaned with a soft, damp cloth. Avoid abrasive cleaners.

Price History

DatePrice
Visit shop