Setup, Compatibility & Care
To install, ensure the water supply is drained and the power circuit to the heating system is isolated. Use standard pipe wrenches to secure the 22mm compression nuts onto your copper pipe. Ensure the flow direction, indicated by an arrow on the valve body, matches your system's water flow. Electrically, the valve typically requires a 230V connection; always follow the wiring diagram provided by your heating controller manufacturer. For maintenance, periodically check for signs of leaks around the compression nuts and ensure the actuator housing remains free of dust or debris. Do not expose the electrical actuator to moisture or direct water spray.