Schneider Electric Modular Contactor - Acti 9 iCT - 16A 2NO 24V AC


Best current price£80.69from eBay
Best offers
Shopping.co.uk recommended and popular offers
eBay£80.69Visit shop STYCZ.ICT50-16/6-24-2NO A9C22112
Visit shop

Best current price£80.69from eBay
Shopping.co.uk recommended and popular offers
eBay£80.69Visit shop STYCZ.ICT50-16/6-24-2NO A9C22112
Visit shop3 offers from £80.69 - £129.36
View price history by clicking the chart icon.
The Schneider Electric Acti 9 iCT modular contactor is designed for electricians and automation professionals needing reliable remote control for circuits, small motors, and HVAC systems. Its key benefit is providing precise control with 2 normally open contacts and a 24 VAC control voltage, enabling safe and efficient operation. A potential caveat is its specific 24 VAC control voltage requirement, which must be matched to the control system. This contactor offers robust performance with a 16A rating for AC-7a and 6A for AC-7b, a long electrical lifespan, and easy DIN rail mounting.
| Series | Acti 9 iCT |
|---|---|
| Model Part Number | A9C22112 |
| Brand | Schneider Electric |
The control voltage for the Schneider Electric Acti 9 iCT (A9C22112) is 24 VAC.
It can control resistive loads up to 16A (AC-7a rating) and small motor loads up to 6A (AC-7b rating).
It is designed for standard 35mm DIN rail mounting.
The contactor has an electrical lifespan of 100,000 cycles for AC-7A/AC-1 operation.
No, this model (A9C22112) is designed for remote electrical control and does not feature a manual override switch.
It complies with IEC/EN 61095 standards.
Verify that the control voltage supplied to the coil terminals is exactly 24 VAC and that the polarity is correct if applicable. Check wiring connections for looseness or damage.
Ensure the load current does not exceed the rated limits (16A AC-7a / 6A AC-7b). If a fault is suspected, the contactor may need replacement. Check for signs of overheating.
Confirm that the load current is within the specified ratings. Ensure adequate ventilation around the contactor. Check for loose connections which can cause increased resistance and heat.
Setup: Mount the Acti 9 iCT contactor securely onto a standard 35mm DIN rail. Connect the control circuit wiring to the coil terminals, ensuring the 24 VAC supply is correctly applied. Wire the power circuit through the main contacts (2 NO) according to your load requirements (up to 16A AC-7a or 6A AC-7b). Ensure all connections are tight and comply with local electrical codes.
Compatibility: This contactor is compatible with all Acti9 heating and ventilation controls. It is designed for AC networks and requires a 24 VAC control voltage source. Ensure your control system's output matches this specification.
Care: No specific maintenance is typically required for normal operation. Periodically inspect electrical connections for tightness. Keep the device free from excessive dust and moisture. Avoid overloading the contacts beyond their specified AC-7a and AC-7b ratings.