Jung Basic Element Data Socket Twisted Pair - UAE8-8UPOK6



Best current price£35.60from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Jung Basic Element Data Socket Twisted Pair - Uae8-8Upok6
Visit shop


Best current price£35.60from Tameson UK
Shopping.co.uk recommended and popular offers
Jung Basic Element Data Socket Twisted Pair - Uae8-8Upok6
Visit shop3 offers from £35.60 - £53.80
View price history by clicking the chart icon.
This Jung data socket is designed for network professionals and home users seeking reliable, high-speed network connectivity. Its key benefit is supporting transmission rates up to 500 MHz and 10 Gbit/s, ensuring future-proof performance for demanding applications. A potential caveat is its specific compatibility with certain Jung cover series, requiring attention during installation.
| Model Part Number | UAE8-8UPOK6 |
|---|---|
| Brand | JUNG |
This data socket supports transmission rates up to 500 MHz and 10 Gbit/s, corresponding to Cat. 6A, Class EA standards.
Yes, the socket is suitable for PoE+ according to IEEE 802.3at.
It features RJ45 connections for networks and is also suitable for RJ 11/12 connections.
It is compatible with various Jung cover series, including A/AS range, LS 990, AS 500, and CD 500.
The data socket is rated for >= 1000 plug cycles, indicating a high level of durability for repeated connections.
The socket has an IP20 rating, meaning it is protected against solid objects larger than 12.5mm but offers no protection against water.
This socket is designed for flush-mounted boxes. Installation on surface-mounted boxes would require specific adapters or different mounting solutions.
Verify all cable connections to the LSA terminals are secure and correctly paired. Ensure the network cable is not damaged and the correct pinout is used. Test with a known working network cable and device.
Check if the connected network equipment (router, switch, cables) also supports the high speeds (10 Gbit/s / 500 MHz). Ensure the network cable is Cat. 6A or higher and properly terminated. Remove potential sources of interference.
Confirm that the connected network switch or injector supports PoE+ (IEEE 802.3at) and is providing sufficient power. Check the network cable for any damage that might impede power delivery.
Utilize the flexible cable entry from all sides and ensure there is sufficient slack. Avoid forcing the cable into tight bends. Secure the cable gently after termination.
Setup: The data socket is designed for flush mounting. It requires installation into a suitable flush-mounted box. Ensure power is disconnected before beginning any wiring. Connect network cables to the screened LSA connection terminals according to the wiring scheme (e.g., TIA/EIA-568).
Compatibility: This socket is compatible with various Jung cover series, including the A/AS range, LS 990, AS 500, and CD 500. Ensure your chosen cover plate is designed to accommodate this type of data socket.
Care: To clean the socket, use a soft, dry cloth. Avoid using abrasive cleaners or solvents, as they can damage the plastic housing. Ensure connections remain clean and free from dust and debris for optimal performance.